期刊文献+

Relationship between contrast sensitivity and corneal shape following overnight orthokeratology 被引量:5

Relationship between contrast sensitivity and corneal shape following overnight orthokeratology
下载PDF
导出
摘要 AIM: To evaluate the relationship between contrast sensitivity(CS) and corneal shape following overnight orthokeratology(OK). METHODS: We conducted a retrospective clinical study of 80 lens-wearing myopia patients, all of whom had undergone OK and had been evaluated by Orbscan II topography. We measured the surface irregularity index(SIRI) of corneal topography at 3 and 5 mm, the size of the flattened central corneal curvature of OK lens(zone A), the size of the cornea altered by OK lens(zone B), the size of the pupillary area at the corneal level(zone C), the area of crossover between zones A and C(zone AC), the area of crossover between zones B and C(BC), the ratio of BC to B(BC/B), and the ratio of AC to C(AC/C). CS was evaluated using the CSV-1000 with spatial frequencies of 3, 6, 12, and 18 cycles/degree(CPD). RESULTS: Multiple correlation analyses indicated significant negative correlations between CS, zone C, BC/B, and 3-mm SIRI(all P<0.01). There were no significant differences between CS, zone B, AC/A, or 5-mm SIRI(P=0.60, 0.94 and 0.11, respectively). Zone C was negatively correlated with 3, 6, 12, and 18 CPD. 5-mm SIRI were negatively correlated with 6, 12, and 18 CPD. BC/C was negatively correlated with 6 and 18 CPD. AC/C was positively correlated with 3 CPD. CONCLUSION: Zone C, 3-mm SIRI and BC/B affect the CS following overnight OK. AIM: To evaluate the relationship between contrast sensitivity(CS) and corneal shape following overnight orthokeratology(OK). METHODS: We conducted a retrospective clinical study of 80 lens-wearing myopia patients, all of whom had undergone OK and had been evaluated by Orbscan II topography. We measured the surface irregularity index(SIRI) of corneal topography at 3 and 5 mm, the size of the flattened central corneal curvature of OK lens(zone A), the size of the cornea altered by OK lens(zone B), the size of the pupillary area at the corneal level(zone C), the area of crossover between zones A and C(zone AC), the area of crossover between zones B and C(BC), the ratio of BC to B(BC/B), and the ratio of AC to C(AC/C). CS was evaluated using the CSV-1000 with spatial frequencies of 3, 6, 12, and 18 cycles/degree(CPD). RESULTS: Multiple correlation analyses indicated significant negative correlations between CS, zone C, BC/B, and 3-mm SIRI(all P<0.01). There were no significant differences between CS, zone B, AC/A, or 5-mm SIRI(P=0.60, 0.94 and 0.11, respectively). Zone C was negatively correlated with 3, 6, 12, and 18 CPD. 5-mm SIRI were negatively correlated with 6, 12, and 18 CPD. BC/C was negatively correlated with 6 and 18 CPD. AC/C was positively correlated with 3 CPD. CONCLUSION: Zone C, 3-mm SIRI and BC/B affect the CS following overnight OK.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期275-279,共5页 国际眼科杂志(英文版)
关键词 ORTHOKERATOLOGY CONTRAST sensitivity PUPIL size area shaped CORNEA MYOPIA orthokeratology contrast sensitivity pupil size area shaped cornea myopia
  • 相关文献

参考文献2

二级参考文献21

  • 1Xiao Yang,Xingwu Zhong,Xiangming Gong,Junwen Zeng.Topographical Evaluation of the Decentration of Orthokeratology Lenses[J].Eye Science,2005,21(3):132-135. 被引量:10
  • 2谢培英.青少年近视、散光的非手术控制与治疗[J].眼科,2006,15(5):294-298. 被引量:23
  • 3王丹,谢培英,王志昕.日戴和夜戴角膜塑形镜对波前像差的影响[J].眼科,2007,16(5):351-354. 被引量:9
  • 4Cho P, Cheung SW, Edwards MH. Practice of orthokeratology by a group of contact lens practitioners in Hong Kong-Part 1. General overview[ J ]. Clin Exp Optom,2002,85:365-371.
  • 5Sridharan R, Swarhrick H. Corneal response to short-term, overnight orthokeratology lens wear[ J]. Optom Vis Sci,2003,80 : 200-206.
  • 6Nichols JJ, Mitchell GL,Saracino M. Reliability and validity of refractive error-specific quality-of-life instruments [ J ] - Arch Ophthalmol, 2003, 121 : 1289-1296.
  • 7Nichols JJ, Twa MD, Mitchell GL. Sensitivity of the National Eye Institute refi'active error quality of life instrument to refractive surgery outcomes[ J]. J Cataract Refract Surg,2005,31:2313-2318.
  • 8McDonnell PJ, Mangione C, Lee P. Responsiveness of the national eye institute refractive error quality of life instrument to surgical correction of refractiw" emu'[ J ]. Ophthalmology ,2003,1 10 : 2302 -2309.
  • 9Chan B,Cho P, Cheung SW. Orthokeratology practice in children in auniversity clinic in Hong Kong[J]. Clin Exp Optom, 2008,91:453-460.
  • 10Rempt F, Hoogerheide J, Hoogenboom WP. Peripheral retinoscopy and the skiagram [ J]. Ophthalmologica, 1971 , 162 : 1-10.

共引文献42

同被引文献58

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部