摘要
以大型双水内冷汽轮发电机为研究对象,对发电机定子铁心采用全出风、抽风式、两进三出和五进六出等四种通风方式的通风特性、铁心温升进行比较,为新产品设计和开发提供参考。
Taking the large-size double-water inner- cooled turbine generator as an example, the ventilation feature and core temperature-rise of four types of ventilation way, single discharge zone, single intake zone, two intakes/three discharge and five intakes/six discharge, were compared, to provide the reference for the design of new products.
作者
崔阳阳
郑东平
胡磊
CUI Yangyang;ZHENG Dongping;HU Lei(Shanghai Electric Power Gen eration Equipment Co.,Ltd Generator Plant)
出处
《电机技术》
2018年第6期12-16,共5页
Electrical Machinery Technology
关键词
双水内冷汽轮发电机
定子铁心
通风方式
风区
double-water
inner-cooled turbine
generator
stator core
ventilation way
ventilation zone