期刊文献+

波长色散X射线荧光光谱法测定磷酸酯抗燃油中氯含量 被引量:3

WD-XRF determination of chlorine content in phosphate ester based fire-resistant hydraulic fluid
原文传递
导出
摘要 建立了基于波长色散X射线荧光光谱法(WD-XRF)测定磷酸酯抗燃油中的氯含量的方法,研究了抗燃油中水分、酸值、矿物油等杂质对测试结果的影响。校准曲线的相关系数为0. 9993,水分和酸值对测试结果基本没有影响,矿物油有稀释作用。方法评价表明检出限为1. 3 mg/kg,定量限为4. 3 mg/kg,相对标准偏差小于5%,回收率为95. 1%~104. 8%。方法已应用于检测近百台次抗燃油中的氯含量,有力支撑了电液调节系统的安全稳定运行。 The method for determination of chlorine content in phosphate ester based fire-resistant hydraulic fluid via wavelength dispersion X-ray fluorescence spectrometry was established. The influences of water content, acid value and mineral oil in fire-resistant hydraulic fluid were investigated. The correlation coefficient of calibration curve was 0. 9993. Water content and acid value have no effect while mineral oil has dilution effect on the results. Method evaluation indicated that the limit of detection is 1. 3 mg/kg,the limit of quantitation is 4. 3 mg/kg,the relative standard deviation is lower than 5%,and the recoveries are between 95. 1% and 104. 8%. This method has been applied to determine nearly one hundred of fire-resistant hydraulic fluid samples.
作者 吴俊杰 周舟 刘凯 曾惠芳 王笑 万涛 龚尚昆 徐松 魏加强 WU Jun-jie;ZHOU Zhou;LIU Kai;ZENG Hui-fang;WANG Xiao;WAN Tao;GONG Shang-kun;XU Song;WEI Jia-qiang(State Grid Hunan Electric Power Company Limited Research Institute, Changsha 410007;Hunan Xiangdian test research institute Co. Ltd, Changsha410004;Human Province Key Laboratory of High Efficient & Clean Thermal Power Technology,Changsha 410007)
出处 《分析试验室》 CAS CSCD 北大核心 2019年第3期290-294,共5页 Chinese Journal of Analysis Laboratory
基金 湖南省科技创新平台与人才计划(2016TP1027) 湖南省湘电试验研究院有限公司项目(XDKY-2014-003)资助
关键词 波长色散X射线荧光光谱 抗燃油 磷酸酯 测定方法 Wavelength dispersive X-ray fluorescence spectrometry ( WD-XRF) Chlorine Fireresistant hydraulic fluid Phosphate Determination method
  • 相关文献

参考文献4

二级参考文献74

共引文献46

同被引文献29

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部