摘要 催化裂化工艺中旋风分离器被用来进行催化剂与油气或与烟气的分离,是保证催化裂化装置长周期安全稳定运行的主要设备。旋风分离器在高温和高浓度的环境下长时间工作有可能发生各种机械故障,例如冲蚀、磨损、断裂、堵塞等,这些故障是导致分离效率下降,催化剂跑损量增大,压力降减小等的主要原因之一。这些不同的机械故障所引起的操作参数变化和跑损催化剂的物性变化是有所不同的,有些参数是突变的,有些是渐变的,还有一些是波动变化的,这些变化与机械故障之间存在着密切联系。可以通过跑损催化剂的浓度和粒度的变化,旋风分离器入口速度和压力降的变化对旋风分离器产生机械故障的原因进行诊断和分析。 Cyclone is operated for separating the catalyst particles from oil vapor or from flue gas in fluid catalytic cracking unit(FCCU),which is key equipment for the long-term operation of the unit.As the cyclone works at high temperature and high concentration for a long time,various mechanical faults may occur,such as erosion,wear,fracture,blocking etc.,which may result in the decrease of separation efficiency,the increase of catalyst loss and the fluctuation of pressure drop.But they are different from mechanical faults,and operating parameters changes and changes of physical properties of lost catalysts are different.Some parameters change abruptly,some parameters change gradually and some parameters change fluctuatingly.These changes are closely related to mechanical faults.The causes of mechanical faults of cyclones can be diagnosed and analyzed based upon the concentration and size distribution of lost catalysts and variations of inlet velocity of cyclone separator and pressure drop.
作者 杨智勇 王菁 赵建章 施玉茜 魏耀东 Yang Zhiyong;Wang Jing;Zhao Jianzhang;Shi Yuxi;Wei Yaodong(College of Chemical & Environmental Engineering,Xinjiang Engineering Institute,Urumqi,Xinjiang 830092;State Key Laboratory of Heavy Oil Processing,China University of Petroleum ( Beijing),Beijing 102249)
出处 《炼油技术与工程》 CAS 2019年第2期37-41,49,共6页 Petroleum Refinery Engineering
基金 国家自然科学基金(21566038)
关键词 催化裂化 旋风分离器 故障 原因 诊断 FCCU cyclone fault cause diagnosis
  • 相关文献

参考文献16

二级参考文献66

共引文献73

同被引文献50

引证文献8

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部