期刊文献+

单元式热力发电机组能耗率评价方法研究

Research on Energy Consumption Evaluation Method of Unit Type Thermal Power Generating
下载PDF
导出
摘要 常规热力机组性能计算方法采集数据量庞大、计算过程繁杂,往往不同单位试验得出的经济指标相差比较大,对机组经济指标准确度判断误导性比较大。采用单元式能量平衡评价方法进行机组性能核算时,可以大幅减少数据采集量和计算步骤,更贴近实际的机组经济指标。 According to the current energy consumption evaluation of unit thermal power generating units,the anti-balance method is used which has the problems of taking many test data,large cumulative error,large deviation of test results and so on.It adopts a method of unit energy consumption balance for thermal power generating.This method has less test data and less cumulative error.It can calculate the energy consumption index of a single generating unit or even the whole power plant simply and accurately.
作者 赵国钦 ZHAO Guoqin(Guangdong Yuedian Jinghai Power Generation Company Limited.,Jieyang,Guangdong 515223,China)
出处 《东北电力技术》 2019年第2期10-14,共5页 Northeast Electric Power Technology
关键词 能耗率 平衡 单元 损失 误差 energy consumption balance unit loss error
  • 相关文献

参考文献1

二级参考文献6

  • 1郑体宽.热力发电厂[M].北京:水利电力出版社,1994.
  • 2石奇光.管道效率的反平衡算法及其分析[M].上海:华东工业大学出版社,1997.
  • 3电力工业部.火力发电厂按人炉煤量正平衡计算发供电煤耗的方法(试行)[S].1993.
  • 4ASME PTC6.0--1996, ASME Steam Turbines Performanee Test Codes[S].
  • 5河北省电力研究院.华润沧州热电公司2×325MW机组出力及性能试验报告[R].2008.
  • 6李岩峰,张海林,徐志明.火电厂管道效率的内涵与在线诊断[J].电力建设,2000,21(7):18-20. 被引量:4

共引文献3