A method of laser focusing control in microlaser-induced breakdown spectroscopy
下载PDF
导出
摘要 This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy. A microscopic optical imaging system consisting of a CCD camera and a 20× objective lens was adopted to realize the method. The real-time auto-focusing of the system was achieved by detecting the effective pixels of the light spot generated by the laser pointer. The focusing accuracy of the method could achieve 3 μm. The element concentrations of Mn and Ni in low-alloy steels were analyzed at a crater diameter of about 35 μm using the presented method. After using the presented method, the determination coefficients of Mn and Ni both exceeded 0.997, with the root-mean-square errors being 0.0133 and 0.0395, respectively. Scanning analysis was performed on the inclined plane and the curved surface by means of focusing control and non-focusing control. Ten characteristic spectral lines of Fe were selected as the analysis lines. With the focusing control, the average relative standard deviations obtained on the inclined plane and curved surface were both less than 5%, and much less than the values without focusing control, 14.6% and 40.39%. This paper presents a method for the automatic adjustment of the laser defocusing amount in micro-laser-induced breakdown spectroscopy. A microscopic optical imaging system consisting of a CCD camera and a 20× objective lens was adopted to realize the method. The real-time auto-focusing of the system was achieved by detecting the effective pixels of the light spot generated by the laser pointer. The focusing accuracy of the method could achieve 3 μm. The element concentrations of Mn and Ni in low-alloy steels were analyzed at a crater diameter of about 35 μm using the presented method. After using the presented method, the determination coefficients of Mn and Ni both exceeded 0.997, with the root-mean-square errors being 0.0133 and 0.0395, respectively. Scanning analysis was performed on the inclined plane and the curved surface by means of focusing control and non-focusing control. Ten characteristic spectral lines of Fe were selected as the analysis lines. With the focusing control, the average relative standard deviations obtained on the inclined plane and curved surface were both less than 5%, and much less than the values without focusing control, 14.6% and 40.39%.
作者 汪为 孙兰香 张鹏 郑黎明 齐立峰 董伟 Wei WANG;Lanxiang SUN;Peng ZHANG;Liming ZHENG;Lifeng QI;Wei DONG
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期31-39,共9页 等离子体科学和技术(英文版)
基金 supported by the National Key Research and Development Program of China (Grant No. 2017YFF0106202) National Natural Science Foundation of China (Grant No. 61473279) the Key Research Program of Frontier Sciences, CAS (Grant No. QYZDJ-SSW-JSC037) the Youth Innovation Promotion Association, CAS
关键词 LIBS MICROANALYSIS ablation CRATER FOCUSING control LIBS microanalysis ablation crater focusing control
  • 相关文献

同被引文献25

引证文献4

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部