期刊文献+

Effect of lens focusing distance on laser-induced silicon plasmas at different sample temperatures 被引量:1

Effect of lens focusing distance on laser-induced silicon plasmas at different sample temperatures
下载PDF
导出
摘要 We investigated the dependence of laser-induced breakdown spectral intensity on the focusing position of a lens at different sample temperatures(room temperature to 300 ℃) in atmosphere.A Q-switched Nd:YAG nanosecond pulsed laser with 1064 nm wavelength and 10 ns pulse width was used to ablate silicon to produce plasma. It was confirmed that the increase in the sample's initial temperature could improve spectral line intensity. In addition, when the distance from the target surface to the focal point increased, the intensity firstly rose, and then dropped.The trend of change with distance was more obvious at higher sample temperatures. By observing the distribution of the normalized ratio of Si atomic spectral line intensity and Si ionic spectral line intensity as functions of distance and temperature, the maximum value of normalized ratio appeared at the longer distance as the initial temperature was higher, while the maximum ratio appeared at the shorter distance as the sample temperature was lower. We investigated the dependence of laser-induced breakdown spectral intensity on the focusing position of a lens at different sample temperatures(room temperature to 300 ℃) in atmosphere.A Q-switched Nd:YAG nanosecond pulsed laser with 1064 nm wavelength and 10 ns pulse width was used to ablate silicon to produce plasma. It was confirmed that the increase in the sample's initial temperature could improve spectral line intensity. In addition, when the distance from the target surface to the focal point increased, the intensity firstly rose, and then dropped.The trend of change with distance was more obvious at higher sample temperatures. By observing the distribution of the normalized ratio of Si atomic spectral line intensity and Si ionic spectral line intensity as functions of distance and temperature, the maximum value of normalized ratio appeared at the longer distance as the initial temperature was higher, while the maximum ratio appeared at the shorter distance as the sample temperature was lower.
作者 张丹 陈安民 王秋云 王莹 李苏宇 姜远飞 金明星 Dan ZHANG;Anmin CHEN;Qiuyun WANG;Ying WANG;Suyu LI;Yuanfei JIANG;Mingxing JIN
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期69-76,共8页 等离子体科学和技术(英文版)
基金 support by National Natural Science Foundation of China (Grant Nos. 11674128, 11504129, and 11474129) Jilin Province Scientific and Technological Development Program, China (Grant No. 20170101063JC) the Thirteenth Five-Year Scientific and Technological Research Project of the Education Department of Jilin Province, China (2016, No. 400)
关键词 LASER-INDUCED BREAKDOWN spectroscopy initial sample temperature DISTANCE between FOCAL point and target surface laser-induced breakdown spectroscopy initial sample temperature distance between focal point and target surface
  • 相关文献

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部