摘要 试验采用稀王水溶解高铅铜合金轴瓦样品,用2%的硝酸作为稀释液稀释样品,在铅217. 000 nm,锡235.495 nm处使用电感耦合等离子体原子发射光谱法进行分析,各元素的相关系数均大于0.999 5,方法的检出限为0.010 5%~0.015 9%(质量分数),结果的相对标准偏差(RSD,n=11)为1.11%~2.28%。进行加标回收试验,加标回收率为97%~102%,测定结果与使用YS/T475.2—2005和YS/T475.1—2005测定结果相符。测定方法的分析范围铅含量为10%~30%,锡含量为0.5%~4.5%。 Test using dilute aqua regia dissolving high lead copper alloy bearing samples, as diluent dilution sample with nitric acid of 2%, the lead is 217.000 nm, tin 235.495 nm using inductively coupled plasma atomic emission spectrometry is analyzed, the correlation coefficient of each element were greater than 0.999 5, the method detection limit of 0.010 5%- 0.015 9%(mass fraction), the results of relative standard deviation (RSD, n = 11) of 1.11% to 1.11%. Standard addition recovery test of standard addition recovery was 97%~ 102%, the determination results with YS/T475.2-2005 is consistent with the results determined by YS/T475.1-2005. Method analysis of the scope of lead is 10%~30%, tin is 0.5%~4.5%.
作者 姜玉领 郭进京 徐艳玲 赵慧 Jiang Yuling;Guo Jinjing;Xu Yanling;Zhao Hui(ZhongYuanNeiPei Corporation)
出处 《河南冶金》 2019年第1期17-19,45,共4页 Henan Metallurgy
关键词 高铅铜合金 轴瓦 电感耦合等离子体原子发射光谱法 Shigh lead copper alloy bushing ICP-AES lead tin
  • 相关文献

参考文献7

二级参考文献24

  • 1张金环,束生庚.火焰原子吸收法测定食品中锡[J].环境与健康杂志,2000,17(z1):18-19. 被引量:2
  • 2匿名著者,GB8002.1-87,1987年
  • 3汪尔康,示波极谱及其应用,1984年
  • 4何光荣,理化检验.化学分册,1983年,19卷,5期,46页
  • 5章泳华,无机去极剂半波电位表(译),1961年
  • 6沙代提.火焰原子吸收法测定铍铜合金中微量铅[J].新疆有色金属,2007,30(A01):85-85. 被引量:4
  • 7汪尔康.与极谱仪联用补偿iR电位降装置[J]分析化学,1978(05).
  • 8GB5121.10—2008,铜及铜合金化学分析方法第10部分:锡含量的测定[S].
  • 9柳志龙,张国莹,等.微克量铜合金中铜、锌、锡、铅、镍的原子吸收测定法[J].冶金分析,1986,6(4):48-50.
  • 10傅水玉,袁亚丽,沈彩芳,等.微波消解-火焰原子吸收测定标准物质贻贝、海带、黄鱼中的铜、铁、钾、镁[J].理化检验(化学分册),2002,38(增刊):112~113.

共引文献16

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部