摘要
建立了快速消解-电感耦合等离子体质谱法(ICP-MS)测定土壤中痕量镉的分析方法,选择^(114)Cd谱线扣除^(118)Sn的光谱干扰,用^(103)Rh做内标进行检测。该法检出限为0.002 mg/kg,精密度为2.9%~4.6%,加标回收率为89.7%~106.6%,方法准确可靠、高效环保,适用于大批量土壤样品的分析。
A method to determine concentrations of trace amounts of cadmium in soil by inductively coupled plasma mass spectrometry(ICP-MS)with rapid digestion was developed.The 114Cd spectral lines were selected to eliminate line interference of 118Sn,and the 103Rh was used as internal standard.The detection limit was 0.002 mg/kg,the relative standard deviation were 2.9%-4.6%,and the recoveries rate were 89.7%-106.6%.The detection method was accurate,reliable,efficient and environmental friendly,which was suitable for the analysis of large batches of soil samples.
作者
黄赛
HUANG Sai(Haimen Comprehensive Inspection and Testing Center in Jiangsu Province,Haimen Jiangsu 226100)
出处
《现代农业科技》
2019年第7期173-174,共2页
Modern Agricultural Science and Technology
关键词
快速消解
ICP-MS
镉
干扰消除
rapid digestion
ICP-MS
cadmium
interference elimination