摘要 以飞机典型电气线路互联系统(ElectricalWiringInterconnectionSystem,EWIS)故障件和线缆及微动开关的南海环境暴晒试验结果为依据,研究了海洋环境下EWIS的腐蚀故障规律、腐蚀类型和形成原因、及电气性能变化规律等。结果表明,海洋环境下EWIS腐蚀失效形式多样,易导致间歇式故障频发,电气性能及屏蔽效能下降等。从适海性的角度提出了应从选材、设计、使用维护和故障数据分析利用等方面来提高EWIS的海洋环境适应性。 Based on fault results of the Electrical Wiring Interconnection System (EWIS) and the South China Sea environmental exposure test results of the aircraft's typical Electrical Wiring Interconnection System (EWIS), the corrosion failure law, corrosion types and causes, and electrical performance variation law of EWIS in marine environment were studied. The results show that the failure modes of EWIS corrosion in marine environment were various, which can easily lead to frequent intermittent faults and decrease of electrical performance and shielding effectiveness. From the point of view of seaworthiness, it is proposed to improve the marine environmental adaptability of EWIS from material selection, design, operation and maintenance, and analysis and utilization of fault data.
作者 郁大照 温德宏 王琳 王腾 王泗环 YU Da-zhao;WEN De-hong;WANG Lin;WANG Teng;WANG Si-huan(School of Basic Science for Aviation, Naval Aviation University, Yantai 264001, China;Aeronautical Equipment Department of Naval Equipment Department, Beijing 100071, China)
出处 《装备环境工程》 CAS 2019年第4期46-50,共5页 Equipment Environmental Engineering
关键词 电气线路互联系统 海洋气候环境 环境适应性 腐蚀防护 electrical wiring interconnection system marine climate environment environmental adaptability corrosion prevention
  • 相关文献

参考文献10

二级参考文献43

共引文献104

同被引文献85

引证文献7

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部