期刊文献+

电动足浴器常见安全隐患分析 被引量:1

Analysis of Common Safety Problems of Electric Foot Bath Machine
下载PDF
导出
摘要 本文主要从安规的角度,结合电动足浴器中较为典型的结构特点,分析了电动足浴器检测中经常出现的问题,包括水温超标、温度传感器与强电部分隔离不充分、电路板和水循环布局不合理、焊点脱落问题以及电气间隙和爬电距离不够。指出了这些问题中隐藏的安全风险同时给出了相应的整改措施。 Considering the safety regulations, some common safety risks of electric foot bath machine are analyzed combined with the structural characteristics of electric foot bath machine, including the water temperature exceeding the standard value, insufficient isolation between temperature sensors and electric parts, unreasonable layout of circuit boards and water circulation, solder joint shedding and insufficient creeping distances and clearance, the hidden danger in these problems are pointed out, in the same time, corresponding corrective measures are given.
出处 《日用电器》 2019年第4期28-30,37,共4页 ELECTRICAL APPLIANCES
关键词 电动足浴器 安全 隐患 electric foot bath machine safety hidden danger
  • 相关文献