期刊文献+

VTIQ新技术定量检测正常大鼠肾脏实质与集合系统的价值 被引量:3

Quantitative detection of renal parenchya and collecting system in normal rasts by VTIQ new technique
下载PDF
导出
摘要 目的研究VTIQ新技术在定量检测大鼠肾脏实质与集合系统中的价值。方法选取40只正常雄性大鼠,根据体重的不同分为低体重组和高体重组,每组各20只,应用VTIQ新技术测量正常大鼠肾脏实质及集合系统的剪切波速度值(Vs)并进行比较,分析不同侧别和体重对Vs值的影响。结果不同侧别、体重的正常大鼠肾实质、集合系统同一部位的Vs值差异无统计学意义(P>0.05)。正常大鼠肾实质与肾集合系统之间的Vs值差异有统计学意义(P<0.05)。结论 VTIQ新技术可以定量反映正常大鼠肾脏实质与集合系统弹性系数的差异,可为进一步深入研究各种肾脏疾病提供一种全新、无创、定量的检测手段。 Objective To study the value of VTIQ in quantitatively detecting renal parenchyma and collection system in rats. Methods Forty normal male rats were selected and divided into low body weight group and high body weight group according to their weight, twenty rats in each group. The shear wave velocity values(Vs) of the renal parenchyma and collection system of normal rats were measured and compared, using the new VTIQ technology to analyze the influence of different sides and body weight on Vs values. Results There was no significant difference in the Vs values of the renal parenchyma and the same part of the collecting system of normal rats with different lateral groups and weights(P>0.05). There were statistically significant differences in Vs values between the renal parenchyma and the renal collecting system in normal rats(P<0.05).Conclusion The new VTIQ technique can provide a new, non-invasive and quantitative detection method for further study of various renal diseases by quantitatively differentiating the elastic coefficient of renal parenchyma and the aggregate system in normal rats.
作者 孙晓颖 邝斌 李明星 赵丽 罗志建 SUN Xiaoying;KUANG Bin;LI Mingxing;ZHAO Li;LLO Zhijian(Department of Ultrasound Diagnosis , The Affiliated Hospital of Southwest Medical University, Luzhou 646000, Sichuan, China)
出处 《西部医学》 2019年第4期518-521,共4页 Medical Journal of West China
基金 四川省科技厅与泸州市人民政府 西南医科大学联合科研基金(14JC0187)
关键词 弹性成像技术 声触诊组织量化技术 声触诊组织成像量化技术 肾实质 肾集合系统 Elastography VTQ VTIQ Renal parenchyma Rendezvous system
  • 相关文献

参考文献4

二级参考文献42

  • 1范春芝,安力春,徐建红,王真,孙静,唐杰,温朝阳.实时定量超声弹性成像技术检测肱二头肌横切面与纵切面弹性差异[J].中华医学超声杂志(电子版),2011,8(5):1039-1047. 被引量:16
  • 2蒋镭,吕继成,陈文芳,王素霞,邹万忠,刘刚,张宏,王海燕.IgA肾病简明半定量病理评分方法及其与预后的关系[J].中华肾脏病杂志,2007,23(5):278-282. 被引量:40
  • 3Fraquelli M, Rigamonti C, Casazza G, Conte D, Donato MF, Ronchi G, Colombo M. Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver disease. Gut 2007; 56:968-973.
  • 4Castera L, Vergniol J, Foucher J, Le Bail B, Chanteloup E, Haaser M, Darriet M, Couzigou P, De Ledinghen V. Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C. Gastroenterology 2005; 128:343-350.
  • 5Chang J, Tan HH, Yew BS. Transient elastography (FibroScan) to assess hepatic fibrosis in Chinese with chronic hepatitis B. 17th Asian Pacific Association for the Study of Liver Conference. 2007.
  • 6Kim KM, Choi WB, Park SH, Yu E, Lee SG, Lim YS, Lee HC, Chung YH, Lee YS, Suh DJ. Diagnosis of hepatic steatosis and fibrosis by transient elastography in asymptomatic healthy individuals: a prospective study of living related potential liver donors. J Gastroentero12007; 42:382-388.
  • 7Ziol M, Handra-Luca A, Kettaneh A, Christidis C, Mal F, Kazemi F, de Ledinghen V, Marcellin P, Dhumeaux D, Trinchet JC, Beaugrand M. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis C. Hepatology 2005; 41:48-54.
  • 8Roulot D, Czernichow S, Le Clesiau H, Costes JL, Vergnaud AC, Beaugrand M. Liver stiffness values in apparently healthy subjects: influence of gender and metabolic syndrome. J Hepatol 2008; 48:606-613.
  • 9Rifai K, Bahr MJ, Mederacke I, Bantel H, Bayer D, Boozari B, Wedemeyer H, Manns MP, Gebel M. Acoustic Radiation Force Imaging (ARFI) as a new method of Ultrasonographic elastography allows accurate and flexible assessment of liver stiffness. Copenhagen: Poster presentation EASL, 2009.
  • 10Poynard T, Halfon P, Castera L, Charlotte F, Le Bail B, Munteanu M, Messous D, Ratziu V, Benhamou Y, Bourliere M, De Ledinghen V. Variability of the area under the receiver operating characteristic curves in the diagnostic evaluation of liver fibrosis markers: impact of biopsy length and fragmentation. Aliment Pharmacol Ther 2007; 25:733-739.

共引文献161

同被引文献23

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部