摘要
以印染废水的COD和浊度为指标,考察氧化-混凝法(Fenton试剂-PAFC-CPAM)处理印染废水的效果。试验结果表明,Fenton试剂单独处理印染废水时,在pH值为4,FeSO4和H2O2的投加量分别为0.3、1.32g/L时,COD的质量浓度和浊度分别降至602.3mg/L和60NTU。Fenton试剂与PAFC(0.5g/L)联合处理时,COD的质量浓度和浊度分别降至484.6mg/L和38NTU,继续投加6mg/L的CPAM后,COD的质量浓度和浊度分别降至419.9mg/L和25NTU,COD去除率达到了51.22%。Fenton试剂-PAFC-CPAM联合处理印染废水的效果明显优于单一试剂。
Taking COD and turbidity as the research indicators, the test of printing and dyeing wastewater treatment by oxidation-coagulation(Fenton reagent-PAFC-CPAM) was investigated. Under the condition that the pH value was 4, the dosage of FeSO4 and H2O2 were 0.3 and 1.32 g/L, the COD mass concentration and turbidity decreased to 602.3 mg/L and 60 NTU respectively. Using the combined process of Fenton reagent and PAFC(0.5 g/L) to treat the said kind of wastewater, the mass concentration of COD and the turbidity decreased to 484.6 mg/L and 38 NTU respectively, after continuously addition of CPAM with mass concentration of 6 mg/L, the above indicators decreased to 419.9 mg/L and 25 NTU respectively, the removal rate of COD reached 51.22%. It could be seen that, compared to single reagent, combined process of Fenton reagent-PAFC-CPAM could obtain better treatment effect when treating printing and dyeing wastewater.
作者
张晓东
李乐
赵磊
沈丽娜
陆曦
朱辉
孙永军
ZHANG Xiao-dong;LI Le;ZHAO Lei;SHEN Li-na;LU Xi;ZHU Hui;SUN Yong-jun(Shanxi Wiser Technology Institue Co., Ltd.,Taiyuan 030000, China;NJUT Environment Technology Co., Ltd., Nanjing 210009, China;College of Urban Construction, Nanjing Tech University, Nanjing 211800, China)
出处
《工业用水与废水》
CAS
2019年第2期23-27,共5页
Industrial Water & Wastewater
基金
国家重点研发计划资助项目(2017YFB0602500)
山西省科技重大专项(MH2015-08)
关键词
FENTON试剂
印染废水
联合处理
Fenton reagent
printing and dyeing wastewater
combined treatment