某工业园区粉煤灰综合利用企业的蒸汽凝结水作为热电厂2号冷却塔循环冷却水系统的补水水源之一,该企业生产过程中发生碱液漏入凝结水,进而造成热电厂循环冷却水严重污染。介绍了污染源的查找、分析过程,以及循环冷却水系统受到污染后采取的措施。
A fly ash comprehensive utilization company in an industrial park using steam condensation water as one of its make-up water source for circulating cooling water system of thermal power plant No.2 cooling tower. During the production process, alkali liquor leakage happened which caused severe pollution of the circulating cooling water of the said thermal power plant. The process of pollution source searching and analysis, as well as the measures that adopted to control the pollution were introduced.
作者
韩志远
HAN Zhi-yuan(Inner Mongolia Datang International Tuoketuo Power Generation Co., Ltd., Hohhot 010206, China)
出处
《工业用水与废水》
CAS
2019年第2期46-48,72,共4页
Industrial Water & Wastewater
关键词
热电厂
循环冷却水
多水源补水
碱液泄漏
thermal polwer plant
circulating cooling water
multi-water sources make-up water
alkali liquor leakage