期刊文献+

330 MW机组锅炉一次风机滚动轴承异常振动诊断及处理 被引量:4

Diagnosis and Treatment of Abnormal Vibration of Rolling Bearing on Primary Fan for 330 MW Boiler
下载PDF
导出
摘要 内蒙古国华准格尔发电有限责任公司2号机组一次风机启动时,2号轴承水平振动超标。根据轴承振动频谱图分析及轴承故障频率监测,确定2号轴承振动大原因为轴承配合间隙增大、1号轴承存在严重缺陷。调整2号轴承间隙并更换1号轴承后,轴承振动恢复正常,保证了设备的长期安全稳定运行。 When unit 2 of Inner Mongolia Guohua Zhungeer Power Generation Co.,Ltd.started a fan,the horizontal vibration of bearing No.2 exceeded the standard level.Based on the analysis of the vibration spectrum of the bearing and the frequency monitoring of the bearing failure,it was determined that the main reason for the vibration of bearing No.2 was the increase of the bearing gap and the serious defect of bearing No.1.After adjusting the clearance of No.2 bearing and replacing No.1 bearing,the bearing ran normally,which guaranteed the long-term safe and stable operation of the equipment.
作者 赵耀俊 田帅 ZHAO Yaojun;TIAN Shuai(Inner Mongolia Guohua Zhuanger Power Generation Co.,Ltd.,Ordos 010300,China)
出处 《内蒙古电力技术》 2019年第2期97-100,共4页 Inner Mongolia Electric Power
关键词 一次风机 滚动轴承 振动频谱 故障频率 冲击能量值 primary fan rolling bearings vibration spectrum frequency of failure impact energy value