摘要 采用过氧化钠碱熔,用电感耦合等离子体质谱法测定铌钽矿中的铌,选择了仪器的最佳工作条件,以10ng/m L铑为内标校正铌,该方法铌的检出限为0.168μg/g。该方法克服了酸分解法溶解不完全而导致分析结果偏低。缩短了分析周期,方法简便、准确、适应性强且更符合环保要求。 The niobium in niobium tantalum ore was determined by sodium peroxide fusion, inductively coupled plasma mass spectrometry, the optimum working conditions of the instrument were selected, and niobium was corrected with 10 ng/m L rhodium as the internal standard, and the detection limit of niobium was 0.168 μg/g. This method overcomes the incomplete dissolution of acid decomposition method and leads to low analysis results. Shorten the analysis cycle, the method is simple, accurate, adaptable and more in line with environmental requirements.
作者 韩文娟 王明芳 耿海燕 母章 白建军 Han Wenjuan;Wang Mingfang;Shan Haiyan;Master;Bai Jianjun(Test chamber, Xinjiang Institute of Mineral Experiments, Urumqi 830000;Xinjiang Uygur Autonomous Region Analysis and Testing Institute Environment Institute, Urumqi 830000, China)
出处 《广东化工》 CAS 2019年第8期179-180,175,共3页 Guangdong Chemical Industry
关键词 碱熔 电感耦合等离子体质谱法 铌钽矿 alkali melt inductively coupled plasma mass spectrometry niobium tantalum ore niobium
  • 相关文献

参考文献1

二级参考文献5

  • 11,P Allain,L Jaunault,Y Mauras,J M Mermet,T Delaporte.Anal.Chem.,1991,63:1497
  • 22,J Goossens,F Vanhaecke,L Moens,R Dams.Anal.Chim.Acta,1993,280:137
  • 33,R M Olivas,C R Quetel,O F X Donard.J.Anal.At.Spectrom., 1995,10:865
  • 44,E H Larsen,S Sturup.J.Anal.At.Spectrom.,1994,9:1099
  • 55,L Liorente,M Gomez,C Camara.Spectrochim.Acta,1997,52B: 1825

共引文献23

同被引文献21

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部