摘要 为节约火电厂厂用电耗,基于660 MW汽轮发电机组,采用罗茨-水环真空泵替换原有水环真空泵,分析不同凝汽器真空严密性条件下两种真空泵的运行功率及对机组经济性的影响。结果表明:罗茨-水环真空泵可有效降低抽真空系统能耗,在真空严密性较好时,能降低原真空泵能耗的66.5%,但当真空严密性变差时,节能效果减弱甚至不节能。 In order to save the power consumption of the thermal power plant,based on the 660 MW steam turbine generator set,the original water ring vacuum pump was replaced by a Roots-water ring vacuum pump.The operating power of the two vacuum pumps and economic impact to steam turbine generator set was analyzed under different vacuum tightness conditions of the condenser.The results showed that the Roots-water ring vacuum pump can effectively reduce the energy consumption.When the vacuum tightness is good,it can reduce the energy consumption of the original vacuum pump by 66.5%.However,when the vacuum tightness deteriorates,the energy saving effect is weakened or even does not exist.
作者 罗海华 谢尉扬 朱宝 周益波 LUO Hai-hua;XIE Wei-yang;ZHU Bao;ZHOU Yi-bo(Zhejiang Energy Group R&D,Hangzhou,China,Post Code:311121;Zhejiang Zheneng Electric Power Co.Ltd.,Hangzhou,China,Post Code:310007;Zhejiang Zheneng Lanxi Power Generation Co.Ltd.,Jinhua,China,Post Code:321100)
出处 《热能动力工程》 CAS CSCD 北大核心 2019年第3期147-151,共5页 Journal of Engineering for Thermal Energy and Power
关键词 罗茨-水环真空泵 凝汽器真空 系统改造 节能 Roots-water ring vacuum pump condenser vacuum systemretrofit energy conservation