采用氮气或干燥空气替代SF6作为绝缘介质是目前环保型柜式气体绝缘金属封闭开关设备(C-GIS)的研究热点。要保证气箱内部结构紧凑、小型化的特征,需要充分掌握气体介质的绝缘特性,寻找电场均匀度对气体高压击穿特性的影响规律。文中研究了在0.10、0.15 MPa压力下,不同电极形式、电极间隙下的两种绝缘气体的正极性雷电冲击耐压特性。数据对比表明:干燥空气相比氮气具有更高的正极性雷电冲击电压击穿特性。同时总结了最大击穿场强E_(max)与电场均匀度刀之间的关系,得到C-GIS绝缘结构设计方面的关键判据。
Using nitrogen and dry air to replace SF6 as the insulation material for eco-friendly cubic gas insulated switchgear(C-GIS) is very popular nowadays. To ensure the characteristics of compact structure and small size, engineers have to fully understand the insulation characteristics of the substitute gases. This article studies the fundamental properties of dry air and N2 as the insulation medium from the respects of different electrode forms or electrodes gaps at 0.1 MPa and 0.15 MPa gas pressures. Comparison of experimental data indicates that the insulation withstand level of dry air is higher than Nitrogen for the positive lightning voltage. Simultaneously, we conclude the relation between the Emax(maximum electric field strength) and the η(electric field utilization) as the critical criterion of the C-GIS insulation structure designing.
作者
李红梅
周柏杰
谭东现
薛健
蔡凡一
肖登明
LI Hongmei;ZHOU Baijie;TAN Dongxian;XUE Jian;CAI Fanyi;XIAO Dengming(Shanghai Ocean University, Shanghai 201306, China;Nari Group Coloration(State Grid Electric Power Research InstituteCo., Ltd.), Nanjing 210000, China;Department of Electric Engineering, Shanghai Jiao Tong University, Shanghai 200030, China)
出处
《高压电器》
CAS
CSCD
北大核心
2019年第4期25-30,共6页
High Voltage Apparatus
关键词
气体绝缘
环保型开关
电场均匀度
最大场强
gas insulation
eco-friendly switchgear
electric field utilization
maximum electric field strength