期刊文献+

医用显示系统的性能评价标准研究

The Study on Performance Evaluation Standards of Medical Display Systems
下载PDF
导出
摘要 医学图像显示器通常是医学成像链的最后阶段。医学图像最初通过成像模块例如X射线、超声(US)、磁共振成像(MRI)、计算机断层扫描(CT)或核医学扫描来创建,用以测量患者的身体或功能特征,并以多维数据集的形式表达出来。文章通过对几种不同医用显示系统评价标准的探讨与对比,分析了我国医用显示器评价标准的优点与不足,旨在提高我国医用显示系统的影像质量。 The medical image display is typically the last stage of a medical imaging chain.Medical images are initially created by imaging modalities such as x-ray,ultrasound(US),magnetic resonance imaging(MRI),computed tomography(CT),or nuclear medicine scans that measure physical or functional attributes of the patient in the form of multidimensional data sets.This paper designed to improve the image quality of medical display systems in China by making contact between several performance evaluation standards on medical display system and analyzing the advantages and disadvantages of China.s medical display evaluation standards.
作者 孟昭阳 孙智勇 王亚南 马跃 金玉博 杨艳 MENG Zhao-yang;SUN Zhi-yong;WANG Ya-nan;MA Yue;JIN Yu-bo;YANG Yan(Liaoning Iinspecton,Examination & Certification Centre,Liaoning Shenyang 110036)
出处 《中国医疗器械信息》 2019年第7期7-9,共3页 China Medical Device Information
基金 国家重点研发计划课题"MRI技术性能评价研究"(项目编号:2016YFC0106904)
关键词 医用显示系统 医用显示器标准 医用显示系统性能评价标准 medical display system medical display standards performance evaluation standards of medical display systems
  • 相关文献

参考文献2

二级参考文献18

  • 1[1]Ehsan Samei,Aldo Badano,et al.Assessment of Display Performance for Medical Imaging Systems.American Association of Physicists in Medicine(AAPM) Task Group18,2002.
  • 2[3]Hans Roehrig,Elizabeth A.Krupinski,and Toshihiko Furukawa.Evaluation of a flat CRT monitor for use in Radiology.Journal of Digital Imaging,Vol14,No3,2001:pp142-148.
  • 3[4]Ehsan Samei,Alan Rowberg,Ellie Avraham and Craig Cornelius.Toward clinically relevant standardization of image quality.Journal of Digital Imaging,Vol17,No4,2004:pp271-278.
  • 4[5]S.Iwano,T.Ishigaki,et al.Detection of subtle pulmonary disease on CR chest images:monochromatic CRT monitor vs color CRT monitor.Eur.Radiol.(2001)11:59-64
  • 5[7]Stephen K.Thompson,Charles E.Willis,et al.Implementing the DICOM Grayscale Standard Display Function for mixed hard-and soft-copy operations.Journal of Digital Imaging,Vol15,Suppl1,2002:pp27-32.
  • 6[8]Elisabeth Oschatz,Mathias Prokop,et al.Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.Eur.Radilo.(2005) 15:1472-1476.
  • 7[9]Ken Compton.Factors affecting cathode ray tube display performance.Journal of Digital Imaging,Vol14,No2,2001:pp92-106.
  • 8[10]Alice N.Averbukh,M.S.,David S.Channin,M.D.,and Michael J.Flynn,Ph.D..Assessment of a novel,high-resolution,color,AMLCD for diagnostic medical image display:luminance performance and DICOM calibration.Journal of Digital Imaging,Vol16,No3,2003:pp270-279.
  • 9[11]NEMA PS 3.14-2000,"Digital Imaging and Communications in Medicine (DICOM) Part 14:Grayscale Display Standard Function",National Electrical Manufactures Association,NEMA.
  • 10[1]Ehsan Samei,Aldo Badano,et al.Assessment of Display Performance for Medical Imaging Systems.American Association of Physicists in Medicine(AAPM) Task Group18,2002.