摘要
对实际非密封储存2、4、6~12年的引信高频部件进行储存性能检测试验,结果表明,高频部件失效存在振荡电压峰峰值降低失效和检波电压降低失效两种;从储存第6年开始出现失效,储存6~12年分别失效4、5、7、10、7、6、10发;振荡电压峰峰值和检波电压均值均有下降趋势,但振荡频率和饱和检波电压未失效。
This paper carried out storage performance test on fuze high-frequency components of actual unsealed storage for 2, 4, 6~12 years. The results show that there are two phenomena of high frequency component failure, such as peaking and lowering of oscillating voltage and failure of detection voltage. Failure occurred from the sixth year of storage, and 4, 5, 7, 10, 7, 6, and 10 failures were stored for 6 to 12 years. The mean value of peak value of oscillating voltage and detection voltage have a downward trend, but the oscillation frequency and the saturation detection voltage have not failed.
作者
王洪岩
吴英伟
路志爽
WANG Hongyan;WU Yingwei;LU Zhishuang(Army Engineering University, Shijiazhuang 050003, China;The No. 63850 th Troop of PLA, Baicheng 137001, China;The No. 32137 th Troop of PLA, Zhangjiakou 075000, China)
出处
《兵器装备工程学报》
CAS
北大核心
2019年第4期124-127,共4页
Journal of Ordnance Equipment Engineering
关键词
电容近炸引信
高频部件
储存性能试验
振荡电压
检波电压
储存失效
capacitance proximity fuze
high frequency component
storage performance test
oscillating voltage
detection voltage
storage failure