摘要 针对某空调机组在进行整机EMC浪涌试验时,内机驱动板所用A厂家整流桥短路失效的问题,本文从整流桥失效机理、器件参数对比、电路设计差异、模拟验证复现等方面进行分析,找出导致驱动板EMC浪涌冲击试验失效的原因。 Aiming at the short-circuit failure of rectifier bridge of manufacturer a used in internal drive board of an airconditioning unit during EMC surge test,this paper analysed the failure mechanism of rectifier bridge,the comparison of device parameters,the difference of circuit design and the recurrence of simulation verification,and found out the reasons for the failure of EMC surge test of driving board.
作者 冯勇雄 王小龙 FENG Yongxiong;WANG XiaoLong(Gree Electric Appliances(Zhuhai)Co., Ltd.,Zhuhai Guangdong 519000)
出处 《河南科技》 2019年第2期41-43,共3页 Henan Science and Technology
关键词 EMC 整流桥 电容 充放电 静电 电路设计 EMC rectifier bridge capacitor charge and discharge static electricity circuit design