摘要 The models for calculating the heat transfer in converters allow the accurate control of heat dissipation caused by downtime,and thus help in crease scrap ratio and reduce energy consumptio n.ANSYS 17 was used to establish such a model to analyse the coupling law between the downtime and heat dissipation of the converter and the temperature drop of molten iron.Temperature was measured by infrared detection,and model accuracy was verified by comparative analysis.The variation law of the amount of cold charge added for different downtimes under different process conditions was studied.The results show that the range of the variation of heat dissipation caused by downtime is 8.9-78.5 GJ.If the downtime increases by 30 min,heat dissipation of dephosphorisation(deP)and decarburisation(deC)converters increases by about 23.4 and 41.3 GJ,respectively.In a certain smelting cycle,the temperature drop of the molten iron for deP,deC and conventional converters increases by about 12.5,15.0 and 17.0 K,respectively;and the amount of scrap added in the double-linking and conventional smelting processes decreases by 0.93 and 0.75%,respectively.
出处 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2019年第3期251-258,共8页 钢铁研究学报(英文版)
基金 National Natural Science Foundation of China(Grant Nos.51674030 and 51574032) National Key Research and Development Program of China(Grant No.2016YFB0601301).