期刊文献+

Influence of preoperative astigmatism on corneal biomechanics and accurate intraocular pressure measurement after micro-incision phacoemulsification 被引量:1

Influence of preoperative astigmatism on corneal biomechanics and accurate intraocular pressure measurement after micro-incision phacoemulsification
下载PDF
导出
摘要 AIM: To define the corneal hysteresis(CH), corneal resistance factor(CRF), Goldmann-correlated intraocular pressure(IOPg) and corneal compensated intraocular pressure(IOPcc) prior to and following coaxial micro-incision phacoemulsification in patients with corneal astigmatism. METHODS: Of 97 patients with cataracts were enrolled in the study. Group 1 included patients with corneal astigmatism(K1-K2) values of K1-K2<+1.0 D, and group 2 with values of K1-K2 ≥+1.0 D and ≤+2.25 D. Coaxial micro-incision phacoemulsification of a corneal incision of 2.0 mm with intraocular lens(IOL) implantation was performed. CH, CRF, IOPg, IOPcc, waveform score(WS) were measured preoperatively and one week, one month postoperatively using an Ocular Response Analyzer. Axial length(AXL) was calculated by Tomey Optical Biometer OA 2000.RESULTS: Group 1 consisted of 51 patients with mean corneal astigmatism value of +0.49±0.25 D. Group 2 included 46 patients with astigmatism of +1.43±0.43 D. In group 1, CRF(t=2.68, P<0.05), CH(t=2.64, P<0.05) and WS(t=3.51, P<0.05) were significantly lower one week postoperatively, when compared to the preoperative values. CRF significantly decreased(t=3.61, P<0.05) when measured one month following the surgery. In group 2 CH(t=5.92, P<0.05), and WS(t=3.96, P<0.05) were significantly lowered one week after cataract surgery. Moreover, we observed a significant decrease in IOPg(t=2.24, P<0.05), CRF(t=5.05, P<0.05) and CH(t=2.31, P<0.05) one month after phacoemulsification. There was no statistically significant(t=-0.83, P=0.41) difference in AXL between study groups.CONCLUSION: CRF, CH and IOPg are reduced in patients with preoperative corneal astigmatism equal or higher than +1.0 D and lower than +2.25 D. Hence, bias of IOPg measurement in these patients may cause underestimation of the real IOP both before and after cataract surgery. The measurement of IOPcc allows the precise assessment of IOP pre-and postoperatively, independently on corneal astigmatism, CH and CRF values. AIM: To define the corneal hysteresis(CH), corneal resistance factor(CRF), Goldmann-correlated intraocular pressure(IOPg) and corneal compensated intraocular pressure(IOPcc) prior to and following coaxial micro-incision phacoemulsification in patients with corneal astigmatism. METHODS: Of 97 patients with cataracts were enrolled in the study. Group 1 included patients with corneal astigmatism(K1-K2) values of K1-K2<+1.0 D, and group 2 with values of K1-K2 ≥+1.0 D and ≤+2.25 D. Coaxial micro-incision phacoemulsification of a corneal incision of 2.0 mm with intraocular lens(IOL) implantation was performed. CH, CRF, IOPg, IOPcc, waveform score(WS) were measured preoperatively and one week, one month postoperatively using an Ocular Response Analyzer. Axial length(AXL) was calculated by Tomey Optical Biometer OA 2000.RESULTS: Group 1 consisted of 51 patients with mean corneal astigmatism value of +0.49±0.25 D. Group 2 included 46 patients with astigmatism of +1.43±0.43 D. In group 1, CRF(t=2.68, P<0.05), CH(t=2.64, P<0.05) and WS(t=3.51, P<0.05) were significantly lower one week postoperatively, when compared to the preoperative values. CRF significantly decreased(t=3.61, P<0.05) when measured one month following the surgery. In group 2 CH(t=5.92, P<0.05), and WS(t=3.96, P<0.05) were significantly lowered one week after cataract surgery. Moreover, we observed a significant decrease in IOPg(t=2.24, P<0.05), CRF(t=5.05, P<0.05) and CH(t=2.31, P<0.05) one month after phacoemulsification. There was no statistically significant(t=-0.83, P=0.41) difference in AXL between study groups.CONCLUSION: CRF, CH and IOPg are reduced in patients with preoperative corneal astigmatism equal or higher than +1.0 D and lower than +2.25 D. Hence, bias of IOPg measurement in these patients may cause underestimation of the real IOP both before and after cataract surgery. The measurement of IOPcc allows the precise assessment of IOP pre-and postoperatively, independently on corneal astigmatism, CH and CRF values.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期587-591,共5页 国际眼科杂志(英文版)
关键词 CORNEAL ASTIGMATISM CATARACT surgery CORNEAL hysteresis CORNEAL resistance factor INTRAOCULAR pressure corneal astigmatism cataract surgery corneal hysteresis corneal resistance factor intraocular pressure
  • 相关文献

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部