基于HNO3-HF-H2O2消解体系进行微波消解后,利用ICP-MS/ICP-OES进行环境土壤中总磷测试。通过优化仪器参数及采取干扰校正措施,两台仪器校准曲线r均大于0.999,其中ICP-MS方法检出限0.05μg/g,RSD在0.67%~1.22%之间,加标回收率106%~114%;ICP-OES方法检出限在5μg/g,RSD在0.29%~0.61%之间,加标回收率105%~108%。用GSS-13和GSS-10标准样品验证,两台仪器的磷测定值与标准值吻合,微波消解ICP-MS/ICP-OES方法可以满足环境土壤中总磷分析的要求。
Based on the HNO 3 -HF-H2O2 microwave digestion system, determined total phosphorus in environmental soil by ICP-MS/ICP-OES, through optimizing instrument parameters and adopting interference correction measures, the calibration curve of both instrument were greater than 0.999, the detection limit of the ICP-MS was 0.05 μg/g and RSD was 0.67%~1.22%, the recovery rate was 106%~114%, the detection limit of the ICP-OES was 5 μg/g and RSD was 0.29%~0.61%, the recovery rate was 105%~108%. Analyzed the national standard soil samples of GSS-13 and GSS- 10, the measured value of both instrument were consistent with the standard value. The microwave digestion ICP-MS/ICP-OES method could meet the standard of the environmental soil total phos- phorus analysis.
作者
张更宇
吴超
刘静波
Zhang Gengyu;Wu Chao;Liu Jingbo(Jilin City Environmental Monitoring Station, Jilin Jilin 132012, China)
出处
《中国环境管理干部学院学报》
CAS
2019年第2期90-93,共4页
Journal of Environmental Management College of China