期刊文献+

五类家用空调过滤网性能比较 被引量:3

Comparison of Filtering Effects of Five Kinds of Household Air Conditioning Filter Networks
下载PDF
导出
摘要 家用空调过滤网是空调的重要组件,通过研究五类过滤网(尼龙初效过滤网;厚款为3mm薄款为1mm的静电滤棉HEPA初效滤网;折高为12mm的HEPA过滤纸;尼龙初效过滤网与薄款静电滤棉的叠加网)在不同风速(2.4m/s、2.7m/s和3.3m/s)、不同粉尘条件下(不加模拟粉尘和加1g粒径为16.9μm的粉尘)网的前后压差,并测定尼龙初效过滤网、薄款静电滤棉和叠加网对2g模拟粉尘的过滤效率,分析五类过滤网的差异,确定风阻较小且除尘率较高的过滤网。实验结果表明叠加网综合性能最好,过滤效率为69.23%,可为家用空调器过滤网的优化提供参考。 Household air conditioning filter network is an important component of air conditioning,through the study of five kinds of filter net(nylon initial filter net;3mm and 1mm HEPA electrostatic initial filter net;HEPA filter paper with 12mm high;nylon initial filter net with thin HEPA electrostatic initial filter net)at different wind speeds(2.4m/s,2.7m/s and 3.3m/s),different dust conditions(without simulated dust and 1g particle size of 16.9 microns),the pressure difference of the net,and the filtration efficiency of the nylon filter net,the thin electrostatic filter and the superposition net to the 2g simulated dust are measured,and the difference of the five kinds of filter nets is analyzed.The best filter with small wind resistance and high dust removal rate is determined.The results show that the Superimposed network has the highest cost performance and the filtering efficiency is 69.23%,it can provide reference for the optimization of household air conditioner filter screen.
作者 李玉涵 况欣 王勇 Li Yuhan;Kuang Xin;Wang Yong(Chongqing University,Urban construction and environmental engineering,Chongqing,400045)
出处 《制冷与空调(四川)》 2019年第2期123-127,共5页 Refrigeration and Air Conditioning
基金 国家级大学生创新训练项目(项目编号:201710611087)
关键词 空调过滤网 风速 压差 过滤效率 air conditioning filter net wind speed differential pressure filtration efficiency
  • 相关文献

参考文献5

二级参考文献13

  • 1David W. B. . Integrated Assessment of Particulate Control [ J ].Heating Piping Air Conditioning Engineering, 2006, 78 (6) : 28-34.
  • 2办公室及公众场所室内空气质素检定计划指南[Z].香港特别行政区:香港环境保护署,2003:16-18.
  • 3Kowalski W. J.,Bahnfleth W. P. . Airborne -Microbe Filtration inIndoor Environments [ J ]. Heating Piping Air ConditioningEngineering, 2002, 74( 1) : 57-69.
  • 4Charles S., Updated Standard for Air - Filter Testing [ OL ].:Heating Piping Air Conditioning Engineering, http://hpac. com/ventilation- iaq/updated_standard_airfilter/,2008.
  • 5Paul Ninomura, Richard Hermans. Ventilation Standard for HealthCare Facilities [J]. ASHRAE Journal, 2008,50(10) : 52-53,55-56, 58.
  • 6Ten Brinke J.,Selvin S.,Hodgson A. T.,et al. Development ofNew Volatile Organic Compound ( VOC) Exposure Metrics and TheirRelationship to " Sick Building Syndrome" Symptoms [ J ]. IndoorAir, 1998, 8 (3) : 140-152.
  • 7Teng S.,Beard K.,Pourahmad J.,et al. The Formaldehyde Meta-bolic Detoxification Enzyme Systems and Molecular Cytotoxic Mecha-nism in Isolated Rat Hepatocytes [ J]. Chemico-Biological Interac-tions, 2001, 130 (1-3) : 285-296.
  • 8章毅,彭关中.改善室内空气品质,创造绿色室内空气环境[J].洁净与空调技术,2009(2):1-4. 被引量:7
  • 9罗燕伟.医院中央空调机组空气净化消毒系统的设计方案[J].医疗装备,2009,22(12):22-24. 被引量:7
  • 10张有德,李素英,黄晶,王玫,周树丽,李红曼.医院空调通风系统清洗周期探讨[J].中华医院感染学杂志,2011,21(12):2514-2515. 被引量:6

共引文献30

同被引文献19

引证文献3

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部