摘要 针对现有自动扶梯梳齿板安全保护开关检测方案无法测量触发力大小,且需检测人员数量多等问题,设计一种自动扶梯梳齿板安全保护开关触发力测量装置。该装置利用齿轮传动与螺纹推动将扭矩进行二级放大,产生足够的推力或拉力以触发安全保护开关;利用偏心轮产生较大夹紧力以保证有效触发安全保护开关;可适用于水平触发与垂直触发2种型式的安全保护开关。 Based on the analysis of the working principle of the safety protection switch of the comb tooth plate of escalator, aiming at the existing detection scheme of the safety protection switch of the comb tooth plate of escalator which can't measure the magnitude of the triggering force and has many requirements on the number of detection personnel, a kind of measurement device with high efficiency, high precision and low cost is proposed. The device can be used for both horizontal trigger and vertical trigger. The torque is amplified by gear transmission and thread drive to generate enough thrust or tension to trigger the safety switch. The mechanism is compact in design. The design of eccentric wheel is used to generate larger clamping force to ensure that the safety switch can be triggered effectively. The device is helpful to quantify the test of safety protection switch.
作者 林燕 黄子豪 何山 江爱华 Lin Yan;Huang Zihao;He Shan;Jiang Aihua(Guangzhou Academy of Special Equipment Inspection & Testing;Guangdong University of Technology)
出处 《自动化与信息工程》 2019年第1期7-11,共5页 Automation & Information Engineering
基金 广东省质量技术监督局科技计划项目(2018PT10) 广州市质量技术监督局科技项目(2018KJ10)
关键词 自动扶梯梳齿板 安全保护开关 触发力 测量装置 Escalator Comb Tooth Plate Safety Protection Switch Trigger Measuring Device
  • 相关文献

参考文献7

二级参考文献13

共引文献15

同被引文献9

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部