摘要
采用固相萃取-反相高效液相色谱法测定泼尼松龙含量。以甲醇-乙酸缓冲液作为提取液,经OasisHLB固相萃取柱净化,氮吹仪浓缩定容,经液相C18色谱柱分离,在247nm波长下检测。结果表明泼尼松龙线性相关系数为0.9992,变异系数为1.23%,回收率为87.4%~93.7%。
A method was developed for the determination of prednisolone by solid phase extraction and reversed phase high performance liquid chromatography(SPE-RPHPLC).The samples were extracted with a methol-acetate buffer solution,purified by an Oasis HLB SPE column,concentrated and analysised by HPLC on C18 column.The correlation coefficients were of 0.9992 with relative standard deviations of 1.23%,and the recoveries of prednisolone were in the range of 87.4%~93.7%.
作者
张慧
Zhang hui(zhejiang xianju pharmaceutical Co.,Ltd zhejiang xianju 317300)
出处
《云南化工》
CAS
2019年第3期79-80,共2页
Yunnan Chemical Technology
关键词
泼尼松龙
固相萃取
液相色谱
prednisolone
solid phase extraction(SPE)
high-performance liquid chromatography( HPLC)