高层建筑电梯井烟囱效应防火设计探讨 被引量:12

Discussion on fire protection design of elevator shaft chimney effect in high-rise buildings
下载PDF
导出
摘要 介绍了高层建筑电梯井烟囱效应的成因,分析引发的问题,并提出解决方案。针对解决方案中的防火设计难点,提出防火设计优化措施。以某高层建筑为例开展防火设计,设置3个火源位置,考虑电梯竖井高度为51、14、4层的情况,通过数值模拟进行分析验证。结果表明,该防火设计方案能够在缓解烟囱效应的同时限制火灾大规模蔓延,保证人员安全疏散。 This paper introduced the causes of chimney effect of elevator shaft in high-rise buildings, analysed the problems caused,and put forward solutions.Aiming at the difficulty of fire protection design in the solution, the optimization measures of fire protection design were put forward. Taking a high-rise building as an example, fire protection design was carried out. Three fire source locations were set. Considering the elevator shaft height of 51, 14 and4 floors, numerical simulation was carried out to verify the design.The results showed that the fire protection design scheme could mitigate the chimney effect while limiting the large-scale spread of fire and ensuring the safe evacuation of personnel.
作者 谢天光 黄鑫 XIE Tian-guang;HUANG Xin(Tianjin Fire Research Institute of MEM, Tianjin 300381,China)
出处 《消防科学与技术》 CAS 北大核心 2019年第3期352-355,共4页 Fire Science and Technology
基金 国家重点研发计划项目"人员安全疏散智能诱导技术与系统"(2016YFC0800602) 公安部消防局应用创新项目"大型商业综合体消防安全管理研究"(2017XFCX15)
关键词 高层建筑 烟囱效应 电梯井 防火设计 high-rise building chimney effect elevator shaft fire protection design