一字型剪力墙计算长度分析

Analysis on the Effective Length of the Shear-wall Without Flange
下载PDF
导出
摘要 一字型剪力墙在稳定分析中往往被简化为两边支撑的矩形薄板,而高层建筑功能日益复杂,一字型剪力墙实际的稳定分析不能按规范一概而论。从楼板与墙肢长度比值,楼板与剪力墙线刚度比,剪力墙开洞率三个方面着手,通过对一字型剪力墙的稳定分析得出计算长度系数的变化,给工程实际提供参考。 The shear-wall without flange in the stability analysis is often simplified as two sides supported rectangular thin plate,as high-rise buildings function increasingly complex,the shear-wall without flange in the stability analysis actually cannot generalize by norms. Starting from three aspects:the ratio of floor length to wall length,the linear stiffness ratio of floor to shear wall,and the hole opening rate of shear wall, through the stability analysis of the shear-wall without flange,the change of effective length coefficient is obtained,which provides reference for the engineering practice.
作者 李伦 Li Lun(Architectural Design & Research Institute of Guangdong Province Guangzhou 500010,China)
出处 《广东土木与建筑》 2019年第5期13-15,共3页 Guangdong Architecture Civil Engineering
关键词 一字型剪力墙 稳定分析 楼板与墙肢长度比值 楼板与剪力墙线刚度比 剪力墙开洞率 计算长度系数 the shear-wall without flange stability analysis the ratio of floor length to wall length the linear stiffness ratio of floor to shear wall the hole opening rate of shear wall effective length coefficient
  • 相关文献

参考文献2

二级参考文献4

  • 1中华人民共和国建设部.JGJ3-2010高层建筑混凝土结构技术规程[S].北京:中国工业出版社,2010.
  • 2何君毅 林祥都.工程结构非线性问题的数值解法[M].北京:国防工业出版社,1984..
  • 3中华人民共和国建设部.JGJ3—2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2001.
  • 4职玉明.上海大剧院结构设计[J].建筑结构,1999,29(2):41-44. 被引量:11