摘要
通过对某幼儿园进行外墙内、外表面温度测试,分析垂直绿化的实际应用效果。测试结果表明,两个房间的外墙外表面温度最大温差为6.0℃,外墙内表面存在着温差,但其差值基本不变,约为1℃,最大差值为1.1℃,降温效果稳定。垂直绿化能有效改善外墙的热传递,降低建筑外墙的内外表面温度。
Through the temperature test of the inner and outer surface of the outer wall of a kindergarten,the practical application effect of vertical greening was analyzed. The test results show that the maximum temperature difference between the exterior walls of the two rooms is 6.0℃. There is a temperature difference on the inner surface of the exterior wall,but the difference is basically unchanged,which is maintained at about 1℃ and the maximum difference is 1.1℃,heat insulation effect is steady. Vertical greening can effectively improve the heat transfer of exterior wall and reduce the temperature of interior and exterior surface of exterior wall.
作者
张广铭
许燕禄
Zhang Guangming;Xu Yanlu(Guangdong Provincial Academy of Building Research Group Co.,Ltd. Guangzhou 510500,China)
出处
《广东土木与建筑》
2019年第5期88-90,共3页
Guangdong Architecture Civil Engineering
关键词
垂直绿化
室内热环境
测试
隔热
vertical green
indoor thermal environment
test
heat insulation