考虑到交直流混合微网特殊的电气特性和网架结构,建立了交直流混合微网能量优化管理模型。针对交流区和直流区不同的负荷特性,分别对交流区负荷采用直接负荷控制和负荷中断方式,对直流区负荷采用负荷平移方法进行需求侧管理。通过算例验证所建模型适用于交直流混合微网,并能够借助需求侧管理技术提升微网的经济性和供电可靠性。
Considering the special electrical characteristics and grid structure of AC/DC hybrid microgrid, the optimal manage- ment model of AC/DC hybrid microgrid is established. According to the different load characteristics of AC/DC hybrid microgrid in AC and DC area, the direct load control and load interruption is used for AC area load, while the load translation is used for DC ar- ea load. A numerical example shows that proposed model is suit- able for AC/DC hybrid microgrid and can fully use demand side management technology to improve the economy of microgrid and the reliability of power supply.
作者
原亚宁
李琳
YUAN Yaning;LI Lin(Skills Training Center,State Grid Jibei Electric Power Co.,Ltd.,Baoding 071051,China;Baoding Power Supply Company,State Grid Hebei Electric Power Company,Baoding 071000,China)
出处
《电力需求侧管理》
2019年第3期63-68,共6页
Power Demand Side Management
基金
国家自然科学基金重点项目(51337005)~~
关键词
交直流混合微网
需求侧管理
直接负荷控制
负荷平移
可中断负荷
AC/DC hybrid microgrid
demand side manage- ment
direct load control
load translation
interruptible load