期刊文献+

逆变器带脉冲负载运行特性及改进措施 被引量:5

Operating Characteristics and Improvement Measure of Inverter with Pulse Load
下载PDF
导出
摘要 为研究逆变器带脉冲负载运行规律,提升逆变器带脉冲负载性能,首先针对逆变器带脉冲负载系统进行了仿真建模和实验平台的搭建,在仿真和实验的基础上,详细分析了脉冲负载占空比、峰值功率以及开关周期对数字控制PWM逆变器运行规律的影响;针对带脉冲负载时逆变器输出电压波形质量和各运行指标均较差的情况,深入分析得到逆变器数字化离散过程造成的时间延迟和逆变控制器响应速度是影响逆变器带脉冲负载性能的主要因素;在此基础上提出了一种基于多次采样和解耦控制的逆变器改进恒压/恒频(voltage/frequency,V/f)控制,并利用MATLAB/Simuilink仿真进行了验证。 In order to study the operating rules of the inverter with pulsed load and improve the performance of the inverter with pulsed load,the simulation modeling and experimental platform for the inverter with pulsed load system were first established. On the basis of simulation and experiment,the influence of pulse load duty cycle,peak power,and switching period on the operation of digitally controlled PWM inverter is analyzed in detail. In view of the poor quality of the output voltage waveform of the inverter and the poor operation of each operating index with pulse load,the in-depth analysis shows that the time delay caused by the digital discrete process of the inverter and the response speed of the inverter controller are the main factors affecting the performance of the inverter with pulse load. Based on this,an improved voltage/frequency (V/f) control for inverters based on multiple sampling and decoupling control is proposed and verified by MATLAB/Simuilink simulation.
作者 黄家豪 王金全 陈静静 黄克峰 严鋆 HUANG Jia-hao;WANG Jin-quan;CHEN Jing-jing;HUANG Ke-feng;YAN Jun(College of Defense Engineering, PLA Army Engineering University, Nanjing 210007, China;77546 PLA Troops, Lasa 850000, China)
出处 《科学技术与工程》 北大核心 2019年第12期162-169,共8页 Science Technology and Engineering
基金 国家自然科学基金(51807091) 江苏省自然科学青年基金(BK20170753)资助
关键词 三相逆变器 脉冲负载 运行规律 改进恒压/恒频控制 three-phase inverter pulse load operating law improved V/f control
  • 相关文献

参考文献6

二级参考文献50

共引文献618

同被引文献57

引证文献5

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部