摘要
目前给热电供热机组配置热水储热罐可实现"热电解耦",提高机组调峰能力,而斜温层厚度是评价热水储热罐储热效率的一个重要指标。为此,以常压热水储热罐储热过程为例,通过建模与数值模拟研究了入口混合因子对储热罐斜温层厚度的影响。
At present, the thermoelectric heating unit equipped with hot water storage tank can realize "thermoelectric decoupling", which improves the capacity of unit peak regulation. The thickness of the thermocline layer is an important index for evaluating the thermal efficiency of the hot water storage tank. In this paper, taking the heat storage process of atmospheric pressure hot water storage tank as an example, the influence of the inlet mixing factor on the thickness of thermocline layer of the heat storage tank was studied by modeling and simulation.
作者
葛世文
陈峰
GE Shiwen;CHEN Feng(School of Control and Computer Engineering,North China Electric Power University,Baoding 071003,China;Beijing GuoDian ZhiShen Control Technology Co. ,Ltd. ,Beijing 102200,China)
出处
《电工技术》
2019年第7期15-17,共3页
Electric Engineering
关键词
热水储热罐
热电解耦
斜温层厚度
入口混合因子
hot water storage tank
thermoelectric decoupling
thickness of the thermocline layer
inlet mixing factor