期刊文献+

用于输电铁塔的光纤布拉格光栅倾斜传感器 被引量:10

Fiber Bragg Grating Inclination Sensor for Transmission Tower
原文传递
导出
摘要 提出了一种基于嵌入式光纤光栅和碳纤维等强度梁的倾斜传感器。介绍了传感器的测量原理和制作方法,进行了全面的测试。研究结果表明,传感器在±30°量程内的倾斜测量灵敏度达到49.73pm/(°),精度可达0.101°,测量重复性误差仅为0.62%,测量函数的线性拟合度达到0.99992,且抗蠕变和温度补偿能力良好,能满足复杂的电力环境下开展长期倾斜监测的要求。 A new inclination sensor based on embedded fiber gratings and carbon fiber equi-strength beams is proposed.The measuring principle and the manufacture methods of this sensor are first introduced.Then this sensor is fully tested.The research results show that,within a measurement range of±30°,the sensor possesses a sensitivity of 49.73 pm/(°),a measurement accuracy of 0.101°,a repeatability error of 0.62%,and a fitting linear correlation coefficient of 0.99992.Furthermore,the creep resistance and the good temperature compensating abilities are good.The requirement of long-term inclination monitoring under complex electric environments is met.
作者 陈剑 郭永兴 朱方东 熊丽 Chen Jian;Guo Yongxing;Zhu Fangdong;Xiong Li(School of Electrical Engineering,Guangzhou College of South China University of Technology,Guangzhou,Guangdong 510800,China;School of Machinery and Automation,Wuhan University of Science and Technology,Wuhan,Hubei 430081,China;Niyigbo Lianghe Road & Bridge Technology Co.,Ltd.,Ningbo,Zhejiang 315201,China;Key Laboratory of Metallurgical Equipment and Control Technology,Ministry of Education,Wuhan University of Science and Technology,Wuhan,Hubei 430081,China)
出处 《激光与光电子学进展》 CSCD 北大核心 2019年第8期77-82,共6页 Laser & Optoelectronics Progress
基金 国家自然科学基金(51605348)
关键词 光纤光学 光纤光栅 倾斜传感器 输电铁塔 倾斜监测 fiber optics fiber Bragg grating inclination sensor transmission tower inclination monitoring
  • 相关文献

参考文献9

二级参考文献95

共引文献101

同被引文献108

引证文献10

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部