期刊文献+

Mass transfer investigation and operational sensitivity analysis of aminebased industrial CO_2 capture plant 被引量:1

Mass transfer investigation and operational sensitivity analysis of aminebased industrial CO_2 capture plant
下载PDF
导出
摘要 In this article, the industrial process of CO_2 capture using monoethanolamine as an aqueous solvent was probed carefully from the mass transfer viewpoint. The simulation of this process was done using Rate-Base model, based on two-film theory. The results were validated against real plant data. Compared to the operational unit, the error of calculating absorption percentage and CO_2 loading was estimated around 2%. The liquid temperature profiles calculated by the model agree well with the real temperature along the absorption tower, emphasizing the accuracy of this model. Operational sensitivity analysis of absorption tower was also done with the aim of determining sensitive parameters for the optimized design of absorption tower and optimized operational conditions. Hence,the sensitivity analysis was done for the flow rate of gas, the flow rate of solvent, flue gas temperature, inlet solvent temperature, CO_2 concentration in the flue gas, loading of inlet solvent, and MEA concentration in the solvent. CO_2 absorption percentage, the profile of loading, liquid temperature profile and finally profile of CO_2 mole fraction in gas phase along the absorption tower were studied. To elaborate mass transfer phenomena, enhancement factor, interfacial area, molar flux and liquid hold up were probed. The results show that regarding the CO_2 absorption, the most important parameter was the gas flow rate. Comparing liquid temperature profiles showed that the most important parameter affecting the temperature of the rich solvent was MEA concentration. In this article, the industrial process of CO_2 capture using monoethanolamine as an aqueous solvent was probed carefully from the mass transfer viewpoint. The simulation of this process was done using Rate-Base model, based on two-film theory. The results were validated against real plant data. Compared to the operational unit, the error of calculating absorption percentage and CO_2 loading was estimated around 2%. The liquid temperature profiles calculated by the model agree well with the real temperature along the absorption tower, emphasizing the accuracy of this model. Operational sensitivity analysis of absorption tower was also done with the aim of determining sensitive parameters for the optimized design of absorption tower and optimized operational conditions. Hence,the sensitivity analysis was done for the flow rate of gas, the flow rate of solvent, flue gas temperature, inlet solvent temperature, CO_2 concentration in the flue gas, loading of inlet solvent, and MEA concentration in the solvent. CO_2 absorption percentage, the profile of loading, liquid temperature profile and finally profile of CO_2 mole fraction in gas phase along the absorption tower were studied. To elaborate mass transfer phenomena, enhancement factor, interfacial area, molar flux and liquid hold up were probed. The results show that regarding the CO_2 absorption, the most important parameter was the gas flow rate. Comparing liquid temperature profiles showed that the most important parameter affecting the temperature of the rich solvent was MEA concentration.
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第3期534-543,共10页 中国化学工程学报(英文版)
关键词 Carbon dioxide MONOETHANOLAMINE Rate-base model ENHANCEMENT FACTOR Sensitivity analysis Carbon dioxide Monoethanolamine Rate-base model Enhancement factor Sensitivity analysis
  • 相关文献

同被引文献13

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部