期刊文献+

基于序贯概率比检验的爆炸物检测系统

Explosive Detection System Based on Sequential Probability Ratio Test
下载PDF
导出
摘要 设计一种基于标记中子方法的爆炸物检测系统,采用ING-27型中子发生器与硅酸钇镥闪烁晶体(LYSO)γ探测器进行探测,并基于序贯概率比检验(SPRT)方法判别爆炸物.通过对干奶粉、硝铵(AMM)和TNT模拟物进行检测,分析计算测量γ能谱数据中C,N,O三种元素的特征峰,将所得概率比结果与相应的设定阈值ln A和ln B进行比较.结果表明,SPRT方法可应用于爆炸物检测. The explosive detection system based on tagged neutron method was designed. The system used the ING-27 neutron generator and the LYSO γ detector for detection. The explosives were distinguished based on sequential probability ratio test (SPRT) method. The characteristic peaks of C,N, and O elements were analyzed and calculated in the measured γ energy spectrum data of milk powder, ammonium nitrate (AMM) and TNT simulators. The probability ratio results were compared with the corresponding thresholds ln A and ln B . The results show that the SPRT method can be applied to the explosive decision.
作者 刘轩 郭勇 景士伟 李明非 郑彦 高亚东 年瑞雪 LIU Xuan;GUO Yong;JING Shiwei;LI Mingfei;ZHENG Yan;GAO Yadong;NIAN Ruixue(School of Physics,Northeast Normal University,Changchun 130024,China;Department of Forensic Science,Sichuan Police College,Luzhou 646000,Sichuan Province,China)
出处 《吉林大学学报(理学版)》 CAS 北大核心 2019年第3期653-657,共5页 Journal of Jilin University:Science Edition
基金 科技部国家重大科学仪器设备开发专项基金(批准号:2013YQ04086101) 吉林省科技发展计划项目(批准号:20190303101SF) 四川省高校重点实验室开放课题 四川省教育厅重点项目(批准号:16ZA0325)
关键词 序贯概率比检验(SPRT) 爆炸物 能谱 标记中子 sequential probability ratio test (SPRT) explosive energy spectrum tagged neutron
  • 相关文献

参考文献2

二级参考文献17

  • 1郭世平.序贯分析方法在医学研究中的应用[A].见:郭世平.王广义,舒晴编.医学研究中常见的设计、衡量与评价方法[M].长春:白求恩医科大学出版社,1987;97—125.
  • 2施侣元.疾病的筛检及其评价[A].见:钱宇平,吴系科,何尚甫编.流行病学进展[M].第4卷.北京:人民卫生出版社,1986:160-178.
  • 3Sackett DL, Straus SE, Richardson WS,et al. Evidence-based medicine [M]. London, Churchill Libingslone, 2000:67-93.
  • 4C. M. Sim,et at. Fast neutron interrogation system de- velopment for the detection of explosive material. Nu- cl. Instr. and Meth. A 605 ( 1 - 2) (2009) 65 - 68.
  • 5S. Mitra, I. Dioszegi. Development Of An Instrument For Non - Destructive Identification Of Unexploded Ordnance Using Tagged Neutrons - A Proof Of Con- cept Study, IEEE Nuclear Science Symposium and Medical Imaging Conference Valencia, 2011.
  • 6J. E. McFee, A. A. Faust, H. R. Andrews, Per- formance of an improved thermal neutron activation detector for buried bulk explosives, Nuclear Instru- ments and Methods in Physics Research A 712 (2013) 93 - 101.
  • 7Maxim Karetnikov, Anatoly Klimov, Sergey Korotkov, et al. Efficiency of background suppression by tagged neutron technology, Nuclear Instruments and Methods in Physics Research B 261 (2007) 307 - 310.
  • 8P. A. Hausladen, J. S. Neal,J. T. Mihalczo. An al- pha particle detector for a portable neutron generator for the Nuclear Materials Identification System( NMIS), Nuclear Instruments and Methods in Physics Research B 241 (2005) 835 -838.
  • 9D. L. Chichester, M. Lemchak, J. D. Simpson. The API 120: A portable neutron generator for the associ- ated particle technique, Nuclear Instruments and Methods in Physics Research B 241 ( 2005 ) 753 - 758.
  • 10G. Nebbiaa, S. Pesente, M. Lunardon, et al. Per- formanee of a tagged neutron inspection system (TNIS) based on portable sealed generators, Nuclear Instruments and Methods in Physics Research A 533 (2004) 475 - 480.