期刊文献+

400kA铝电解槽阳极电流的测量与分析 被引量:4

Measurement and analysis of anode current in 400kA aluminum reduction pots
下载PDF
导出
摘要 阳极电流是铝电解生产过程中的重要参数,但目前难以对其进行准确测量.本研究中使用光纤电流传感器测量了400kA铝电解槽中的阳极电流.测试结果表明,该方法能有效避免电磁场干扰,电流测量精度高,测量误差在±2%以内.本文对测量数据进行了分析,给出了阳极电流的分布特点以及换极引起的电流分布变化,发现新阳极所在的区域中电流减少20%左右,邻近的两个区域电流则各增加约10%,其它区域的电流变化幅度不大. Anode current is recognized as an important parameter during the aluminum reduction process, but it is currently difficult to acccurately measure the anode current. The fiber - optic current sensor is used in this study to measure the anode current of 400kA aluminum reduction pot. The test result shows that this method can effectively avoid the interference of electromagnetic field, the current can be measured with high precision, and the measure ment error is controlled within ±2%. The measurement data is analyzed in this paper, which shows characteristics of the anode current distribution and the current distribution changes caused by the anode changing. It is found that the current in the new anode area is reduced by about 20%, while the cur rent in the adjacent two areas is increased by about 10%, and the current has little change greatly in other areas.
作者 范洪涛 铁军 曾箐雨 赵任涛 蒙毅 张志芳 Fan Hongtao;Tie Jun;Zeng Qingyu;Zhao Rentao;Meng Yi;Zhang Zhifang(Modern Detection Technology and Device Engineering Center of Nonferrous Metallurgical Process,North China University of Technology,Beijing 100144 ,China)
出处 《轻金属》 北大核心 2019年第4期26-30,共5页 Light Metals
关键词 铝电解槽 阳极电流 电流分布 换极 aluminum reduction pots anode current current distribution anode changing
  • 相关文献

参考文献2

二级参考文献10

共引文献9

同被引文献23

引证文献4

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部