双热释光元件个人剂量计Hp(10)测量不确定度评定

Assessment of uncertainty in Hp(10) measurement by using a double TLD element personal dosimeter
原文传递
导出
摘要 目的介绍双热释光元件个人剂量计Hp(10)测量不确定度评定方法。方法采用GUM法建立测量模型,根据个人剂量计的性能,对个人剂量当量Hp(10)测量不确定度进行评定。结果当测量结果经非线性响应及能量响应等修正时,Hp(10)的相对扩展不确定度Urel为28%;当测量结果未进行非线性响应及能量响应等修正时,Hp(10)的相对扩展不确定度Urel为33%。结论该方法可对常规监测中的个人剂量当量Hp(10)测量不确定度进行有效评定。 Objective To describe the evaluation method of uncertainty in measurement of depth individual dose equivalent.Methods Based on the performance of the personal dosimeter,GUM method was used to evaluate the uncertainty of Hp(10) measurement by using a personal dosimeter.Results The relative extended uncertainty was 28% when the measurement result was corrected by nonlinear response and energy response,as well as 33% when not corrected in the same way.Conclusions This method can be used to effectively evaluate the uncertainty arising from personal dose equivalent Hp(10) measurement in routine monitoring.
作者 张璇 郭文 丁艳秋 胡爱英 陈飞 Zhang Xuan;Guo Wen;Ding Yanqiu;Hu Aiying;Chen fei(Key Laboratory of Radiological Protection and Nuclear Emergency,China CDC,National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China)
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2019年第5期397-400,共4页 Chinese Journal of Radiological Medicine and Protection
关键词 Hp(10) 测量不确定度 GUM法 Hp(10) Uncertainty of measurement GUM method