摘要
介绍了艾灸室对工位排风的要求,并对某一型号排风罩的排风量进行了计算。为了检验其效果,以某艾灸室为对象建立物理模型进行了数值模拟计算。结果表明,艾灸盒排烟点处的风速能够将艾灸烟气带入排风罩内且艾灸部位无吹风感。
Present the requirements of the workplace exhaust in moxibustion chambers,and calculates the exhaust air rate of a certain type of exhaust hood.In order to test its effect,establishes a numerical simulation physical model of a moxibustion chamber.The results show that the wind speed at the exhaust point of the moxibustion box is enough to carry the moxibustion smoke into the exhaust hood and the moxibustion area has no feeling of blowing wind.
作者
王刚
Wang Gang(Hebei University of Science and Technology,Shijiazhuang,China)
出处
《暖通空调》
2019年第5期70-72,98,共4页
Heating Ventilating & Air Conditioning
关键词
工位排风
数值模拟
万向排风罩
艾灸
控制风速
workplace exhaust
numerical simulation
universal exhaust hood
moxibustion
capture velocity