摘要 某核电站在机组特定工况下出现汽动给水泵抽汽调节阀门异常关闭的问题,此时若叠加其他给水系统控制故障,可能引起蒸发器水位大幅波动至低低液位而跳机跳堆。论文结合具体案例详细分析了抽汽调节阀门异常关闭的原因,并针对该原因制定相应的措施。 The abnormal closure of the steampumping regulating valve of a nuclear power plant under specific operating conditionsmay cause the evaporator water level to fluctuate sharply to low liquid level and jump out of the reactor if other control faults of the feed water system are superimposed at this time.In this paper,the causes of the abnormal closure of steamextraction control valves are analyzed in detailwith specific cases,andcorrespondingmeasuresare formulatedfor accordingtothese causes.
作者 王晓峰 WANG Xiao-feng(Daya Bay Nuclear Power Operations and Management Co.Ltd.,Shenzhen 518124,China)
出处 《中小企业管理与科技》 2019年第11期146-148,共3页 Management & Technology of SME
关键词 汽动给水泵 阀门 关闭 措施 steamfeedpump valve close measure