摘要
本文通过调研通信基站机房新风系统的运行现状,以及对比通信基站机房新风系统和空调联合运行的降温措施与用空调单独运行降温措施的节电量,得出通信基站机房新风系统和空调联合运行具有巨大的经济效益、社会效益和环境效益,同时指出通信基站机房新风系统和空调联合运行需要解决的问题。
This paper investigated the operation status of fresh air system in communication base station room and compared energy-saving of communication base station room about cooling measures for combine operation of fresh air system and air conditioning and cooling measures for individual operation with air conditioning respectively, which concluded that the combine operation of fresh air system and air conditioning has great economic benefits, social benefits and environmental benefits in communication base station room. At the same time, it pointed out the problems that need to be solved in the combine operation of fresh air system and air conditioning in communication base station room.
作者
孟山青
李泽奇
Meng Shanqing;Li Zeqi(Beijing Huaqing Kaier Air Purification Technology Co.,Ltd.,Beijing,100176;China Academy of Architectural Sciences Co.,Ltd.,Beijing,100013)
出处
《建设科技》
2019年第9期80-82,共3页
Construction Science and Technology
关键词
通信基站
新风系统
节能减排
communication base station
fresh air system
energy saving and emission reduction