利用天然冷源对数据中心空气调节的探索

Exploring Air Conditioning in Data Centers Using Natural Cold Sources
下载PDF
导出
摘要 当前,能源供应日益紧张,能级对口、阶梯用能、提高能效的科学用能已被认可。通过对数据中心冷热负荷量及用能精度的分析,利用热管式气-气加热器(HGGH)作为精密空调系统的补充,对数据中心进行空气调节;充分利用了低品位能源,实现了数据中心空气调节。在实际应用案例中同样得到证实,技术可行,经济合理。 Today,the energy supply is becoming increasingly tight,and the scientific use of energylevel counterparts, energy-efficient steps, and energy efficiency enhancements has been recognized.Through the analysis of data center ’s cold and heat load and energy use accuracy,the use of heat pipe gas-gas heater( HG G H) technology as a supplement to precise air conditioning systems for data centers;the low-grade energy is fully utilized to achieve air conditioning in the data center. It is also confirmed,the technology is feasible and the cost is reasonable in practical application cases.
作者 李永田 张晓红 王荣尧 吴金 LI Yong-tian;ZHANG Xiao-hong;WANG Rong-yao;WU Jin(Trina Solar Limited by Share Ltd.,Changzhou 213031,Jiangsu,China;China Sinogy Electric Engineering Co.,Ltd.,Shanghai 200061,China)
出处 《建筑节能》 CAS 2019年第5期116-118,148,共4页 BUILDING ENERGY EFFICIENCY
基金 “十三五”国家重点研发计划“可再生能源与氢能技术”重点专项《特色小镇全可再生能源多能互补热电气储耦合供能系统关键技术及示范》(2018FYB1502900)
关键词 空气调节 热管 热管式气-气加热器 数据中心 air conditioning heat pipe heat pipe gas-gas heater(HGGH) data center
  • 相关文献

参考文献6

二级参考文献26

  • 1张华,何强,陈振宇,陈玉乐.湿法烟气脱硫中GGH对污染物扩散影响初探[J].电力环境保护,2005,21(2):1-3. 被引量:43
  • 2SUENAGA T, MATSUURA F. A new air condi- tioning system for telecommunications equipment rooms with high-heat generation density [C]//IEEE. Proc of lnt Telecommun Energy Con f, Piscataway.- IEEE, 1984:532-537.
  • 3NOH H K, SONGKS, CHUNSK. The cooling characteristics on the air supply and return flow sys- tem in the telecommunication cabinet room[C]// IEEE Proc of the 1998 20th Int Telecommun Ener- gy Con f, Piscataway: IEEE, 1998: 777-784.
  • 4ZHANG Y F, CHEN Y, WU J, et al. Study on energy efficient envelope design for telecommunica- tion base station in Guangzhou [J ]. Energy and Buildings, 2008,40(10): 1895-1900.
  • 5CHEN Y, ZHANG Y F, MENG Q L. Study of ventilation cooling technology for telecommunication base stations in Guangzhou[J]. Energy and Build- ings, 2009,41(7) :738-744.
  • 6POREBSKI W, ULFVENGREN R. Passive cooling of small telecommunication enclosures, case study and practical approach [C]// IEEE Proc of the 1998 20th Int Telecommun Energy Con f, Piscat- away: IEEE, 1998..562-567.
  • 7PRUDHOE R K, HENSHAW R, DOUKAS L, et al. Passive cooling of electronic equipment rooms-- thermal diode room construction[C]// IEEE Com- mun Soc IEEE Pow Electronics Soc, IEICE of Ja- pan. Proc of the 13th Int Telecommun Energy Con f, Piscataway: IEEE, 1992..401-409.
  • 8NAKAO M, OHSHIMA K, JITSUKAWA H. Thermal control wall for telecommunication equip- ment rooms[C]// IEEE Cornmun Soc Int Telecom- mun Energy Con f, Piscataway.. IEEE, 1988: 280- 284.
  • 9KHODABANDEH R. Thermal performance of a closed advanced two-phase thermosyphon loop for cooling of radio base stations at different operating conditions[J]. Appl Therm Eng , 2004,24(17-18) : 2643-2655.
  • 10LEE S, KANG H, KIM Y. Performance optimiza- tion of a hybrid cooler combining vapor compression and natural circulation cycles[J].Int J of Refrig, 2009,32(5) :800-808.

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部