期刊文献+

β表面污染的测量因素研究 被引量:3

The Study on Measurement Factors of Beta Surface Contamination
下载PDF
导出
摘要 本文利用CoMo170表面污染监测仪对90Sr-90Y平面源进行测量,研究吸收效应、γ射线干扰等因素对于β表面活度响应值的影响规律。结果发现遮挡塑料布对于β粒子的吸收衰减很显著,而且塑料布越厚,衰减越明显;γ射线的干扰也会对结果造成影响,铝板和有机玻璃板的组合能够有效屏蔽β射线。因此,在β表面污染的实际测量中,须严格按照规定操作测量,针对相关测量因素应引起足够的重视。 This paper uses CoMo170 surface contamination monitor to measure the90 Sr-90 Y plane source,and studies absorption effect and gamma rays interference on the surface activity response.It was found that the absorption attenuation of beta particles by the shielding plastic cloth is significant,and the thicker the plastic cloth is,the more obvious the attenuation is;The interference of gamma rays also has influence on the results,and the combination of aluminum plate and organic glass plate can effectively shield beta rays.Therefore,in the actual measurement of beta surface contamination,the measurement must be carried out in strict accordance with the regulations.
作者 李玉芹 文章 LI Yu-qin;WEN Zhang(China Institute of Atomic Energy,Beijing 102413,China)
出处 《科技视界》 2019年第10期88-88,92,共2页 Science & Technology Vision
关键词 表面污染 测量因素影响 表面活度响应 Beta surface contamination Measurement factors impact Surface activity response
  • 相关文献

参考文献2

二级参考文献3

  • 1(英)克莱顿R F 黄治俭译.放射性表面污染的监测[M].北京:原子能出版社,1976.2-2.
  • 2GB18871-2002,电离辐射防护与辐射源安全基本标准[S].2002.
  • 3GB/T5202-2008辐射防护仪器α、β和α/β(β能量大于60keV)污染测量仪与监测仪[S].北京:中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会,2008.