摘要 文中对地势起伏段管道进行了非接触磁记忆检测及开挖验证,该技术对管体变形引起的应力集中具有较高检测灵敏度,可作为内检测和外检测的互补技术,加强特殊区域埋地管道的完整性管理。 Non-contact magnetic memory detection and excavation verification were carried out for the pipeline in terrain fluctuation.The technique has high detection sensitivity for stress concentration caused by tube deformation,which can be used as a complement for internal and external detection and can strengthen the integrity management of buried pipelines in special areas.
作者 车飞 高海霞 马宝军 张智德 CHE Fei;GAO Hai-xia;MA Bao-jun;ZHANG Zhi-de(Beijing West Tube Inspection Technology Co.,Ltd.,Beijing 100107,China)
出处 《管道技术与设备》 CAS 2019年第3期8-10,共3页 Pipeline Technique and Equipment
关键词 非接触磁记忆 地势起伏 应力集中 异常 non-contact magnetic memory terrain fluctuation stress concentration abnormal
  • 相关文献

参考文献2

二级参考文献8

  • 1郭贻诚.铁磁学[M].北京:人民教育出版社,1982.375-386.
  • 2[3]Sablik M J,Kwun H,Burkhardt G L,and Jiles D C.Model for the effect of tensile and compressive stress on ferromagnetic hys-teresis.J.Appl.phya.1987,61(8):3799-3801.
  • 3[4]Jiles D C,Atherton D L.Theory of ferromagnetic hysteresis[J].Magn.Magn.Mater.,1986,61:48-60.
  • 4[5]Sablik M J,Burkhardt G L,Kwun H,and Jiles D C.A model for the effect of stress on the low-frequency harmonic content of the magnetic induction in ferromagnetic materials[J].Appl.Phys.,1988,63(8):3930-3932.
  • 5[8]Doubov AA.Diagnostics of metal and equipment by meetis of metal magnetic memory[A].Proceedings of ChSNDT 7th Confer-ence on NDT and International Research Symposium[C].Shantou China:1999.181-187.
  • 6任吉林,唐继红,邬冠华,林俊明,林发炳,林春景.金属的磁记忆检测技术[J].无损检测,2001,23(4):154-156. 被引量:57
  • 7任吉林,邬冠华,宋凯,林俊明,陈开惠.金属磁记忆检测机理的探讨[J].无损检测,2002,24(1):29-31. 被引量:88
  • 8仲维畅.金属磁记忆法诊断的理论基础——铁磁性材料的弹-塑性应变磁化[J].无损检测,2001,23(10):424-426. 被引量:57

共引文献29

同被引文献48

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部