摘要 傅里叶变换红外光谱(FTIR)技术已经成为监测大气痕量气体成分的有效方法。使用中国科学院安徽光学紧密机械研究所自主开发的动态自准直开放式FTIR系统对甘肃省庆阳市化工园区进行了连续监测,并在同等条件下将其与国外开放式FTIR仪器的监测数据进行对比分析和性能比较。结果表明,所采用开放式FTIR能够很好地在线实时监测化工园区的污染气体组分,为环境污染治理监督提供了科学监测方法,且在信噪比等方面优于国外相应的开放式FTIR仪器。 Fourier transform infrared spectroscopy(FTIR)technology has become an effective method for monitoring trace gas composition in atmosphere.The dynamic auto-collimation open FTIR system devoloped by Anhui Institute of Optics and Fine Mechamics,CAS,has been used to continuously monitor the atmospheric trace gases in the chemical industrial park in Qingyang city,Gansu Province,China.Continuous monitoring was carried out and compared with the monitoring data of foreign open FTIR instruments under the same conditions.The results show that the open FTIR can monitor the pollution gas components in the chemical park on-line in real time,and provide a scientific monitoring method for environmental pollution control supervision.The domestic open FTIR is superior to the corresponding open FTIR instruments from other foreign countries in terms of signal-noise ratio.
作者 王向锋 贺冬云 黄旭昀 周蓉卉 郭小玮 WANG Xiangfeng;HE Dongyun;HUANG Xuyun;ZHOU Ronghui;GUO Xiaowei(Qingyang Environmental protection research institute,Qingyang 745000,China;Gansu Longhai environmental protection technology service co. LTD.,Lanzhou 730030,China;Zhuhai Guangrui Huili Development Co.,Ltd.,Zhuhai 519000,China;College of Mechanical and Aerospace Engineering,Jilin University,Changchun 130012,China)
出处 《量子电子学报》 CAS CSCD 北大核心 2019年第3期264-269,共6页 Chinese Journal of Quantum Electronics
基金 国家自然科学基金青年基金,41202086~~
关键词 光谱学 红外光谱 傅里叶变换 动态自准直 信噪比 spectroscopy infrared spectroscopy Fourier transform dynamic auto-collimation signal-noise ratio
  • 相关文献

参考文献3

二级参考文献22

  • 1陆思华,白郁华,张广山,李湉湉.大气中挥发性有机化合物(VOCs)的人为来源研究[J].环境科学学报,2006,26(5):757-763. 被引量:127
  • 2徐亮,刘建国,高闽光,陆亦怀,魏秀丽,张天舒,朱军,陈军.开放式长光程傅里叶变换红外光谱系统在环境气体分析中的应用[J].光谱学与光谱分析,2007,27(3):448-451. 被引量:18
  • 3[1]Lee B.Highlights of the clean air act amendments of 1990[J].J.Air Waste Manag.Assoc.,1991,41:16-23.
  • 4[3]Griffith D W T,Galle B.Flux measurements of NH3,N2O and CO2 using dual beam FTIR spectroscopy and the flux-gradient technique[J].Atmos.Environ.,2000,34:1087-1098.
  • 5[4]Shcaefer K,Haus R,Heland J,et al.Measurements of atmospheric trace gases by emission and absorption spectroscopy with FTIR[J].Ber.Bunsen-Ges.Phys.Chem.,1995,99:405-411.
  • 6[5]Fateley W G,Hammaker R M,Tucker M D,et al.Observing industrial atmospheric environments by FTIR[J].J.Mol.Struct.,1995,347:153-168.
  • 7[6]Spartz M L,Witkowski M R,Fateley J H,et al.Evaluation of a mobile FTIR system for rapid VOC determination[J].Am.Environ.Lab.,1989,89:15-30.
  • 8[8]David M H,Robert G E,David A V.Multivariate least-squared methods applied to the quantitative spectral analysis of multicomponent samples[J].App.Spec.,1985,39(1):73-85.
  • 9Schneider S H.Scientific American,1989,261(9):38.
  • 10Paul J Crutzen.Ambio.,1995,24(1):52.

共引文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部