期刊文献+

1000MW机组引风机轴承温度高原因分析及防范措施

Cause Analysis and Preventive Measures for High Temperature Bearing of Induced Fan of 1000MW Unit
下载PDF
导出
摘要 针对某电厂1000MW机组引风机轴承温度高的现象及原因进行分析,通过对引风机轴承检查,提出了轴承油脂选型、检修工序工艺及质量监督管理等防范措施,希望能够确保风机安全可靠运行。 According to the analysis of the high temperature and the cause of the bearing temperature of the 1000 MW unit of a power plant, through the inspection of the bearing of the induced draft fan, the preventive measures such as the selection of the bearing oil, the process of the maintenance process and the quality supervision and management are put forward, and it is hoped that the fan can be safely and reliably operated.
作者 丘晓武 QIU Xiaowu(Guangdong YueDian Jinghai Power Generation Co.,Ltd.,Huilai 515223)
出处 《现代制造技术与装备》 2019年第5期138-139,共2页 Modern Manufacturing Technology and Equipment
关键词 引风机 轴承温度 防范措施 induced draft fan bearing temperature preventive measures