摘要 在实际工业成产工作中,流量测量是一个非常复杂的工作,不能够轻易获得准确参数。随着科技水平不断提高,工业技术水平也日渐提升,在人们生产生活中,对化学工业稳定控制要求也越来越严格,这使得质量流量计受到了工作人员的重视,并在实际的工业成产现场发挥着及其关键的作用。质量流量计优点众多,而其测量精度高、操作性和应用性强的优势使之被运用在了各个行业工业现场中。 In actual industrial production, flow measurement is a very complicated task and it is not easy to obtain accurate parameters. With the continuous improvement of the level of science and technology, the level of industrial technology is also increasing. In people’s production and life, the requirements for stable control of the chemical industry are becoming more and more strict. This makes the mass flowmeters pay attention to the staff and is in actual industrial development. The production site plays a key role. Mass flow meters have many advantages,and their advantages of high measurement accuracy, operability and applicability make them used in industrial fields of various industries.
作者 梁大涛 LIANG Datao(Sinopec Lubricating Oil Company,Beijing 100085)
出处 《现代制造技术与装备》 2019年第5期186-187,共2页 Modern Manufacturing Technology and Equipment
关键词 科氏质量流量计 原理 选型 coriolis mass flowmeter principle selection
  • 相关文献

参考文献3

二级参考文献23

  • 1张海涛,涂亚庆.计及负频率影响的科里奥利质量流量计信号处理方法[J].仪器仪表学报,2007,28(3):539-544. 被引量:40
  • 2中国计量科学研究院.JJG164-2000液体流量标准装置国家计量检定规程[S].北京:中国计量出版社,2000.
  • 3国家质量监督检验检疫总局.JJG1038-2008科里奥利质量流量计检定规程[S].北京:中国计量出版社,2008.
  • 4Anklin M,Drahm W,Rieder A.Coriolis mass flowmeters:Overview of the current state of the art and latest research[J].Flow Measurement and Instrumentation,2006,17(6):317-323.
  • 5Reizner J R.Coriolis-the almost perfect flow meter[J].IEE Computing&Control Engineering,2003,14(4):28-33.
  • 6Gregory D,West M,Paton R,et al.Two-phase flow metering using a large coriolis mass flow meter applied to ship fuel bunkering[J].Measurement and control,2008,41(7):208-212.
  • 7Seeger M.Coriolis flow measurement in two phase flow[J].IEE Computing&Control Engineering,2005,16(3):11-16.
  • 8Reizner J R.Coriolis-the almost perfect flow meter[J].IEE Computing&Control Engineering,2003,14(4):28-33.
  • 9Hemp J,Yeung H.Coriolis meters in two phase conditions[J].IEE Computing&Control Engineering,2003,14(4):36.
  • 10Liu R P,Fuent M J,Henry M P,et al.A neural network to correct mass flow errors caused by two-phase flow in a digital Coriolis mass flowmeter[J].Flow Measurement and Instrumentation,2001,12(1):53-63.

共引文献9

同被引文献3

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部