期刊文献+

心脏永久起搏器的电磁兼容研究进展 被引量:1

Research Progress of the Electromagnetic Compatibility of Cardiac Permanent Pacemaker
下载PDF
导出
摘要 心脏永久起搏器容易受高频电磁信号等干扰,可能会影响起搏器工作,甚至威胁患者安全,然而,随着人口老龄化及近来起搏器植入量逐年增加,越来越多的患者在诊治过程中需要接受磁共振检查、高频电刀等产生电磁干扰(electromagnetic interference,EMI)的医疗器械的诊断及治疗。近来,针对心脏永久起搏器电磁兼容领域的研究取得了显著进展,核磁共振兼容起搏器及可用于起搏器依赖的高频电刀系统的研发取得了显著进展,对此作一综述。 Heart permanent pacemaker was susceptible to interference such as high-frequency electromagnetic signals,which may affect the pacemakers,even threaten patients' safety. However,as the population ages and pacemaker implantation quantity increases year by year recently,more and more patients need to receive magnetic resonance imaging and high-frequency electric knife that produce electromagnetic interference(EMI)in the process of diagnosis and treatment. Recently,there is significant progress in the field of electromagnetic compatibility research on heart permanent pacemaker. Researchers have made significant progress in the development of magnetic resonance imaging compatible pacemakers and high frequency electricity knife which can be used in patients with pacemakers. This article reviews the progress.
作者 丁旭萌 蒲里津 DING Xu-meng;PU Li-jin(Dept. of Cardiology,The 1st Affiliated Hospital of Kunming Medical University,Kunming Yunnan 650032,China)
出处 《昆明医科大学学报》 CAS 2019年第4期1-5,共5页 Journal of Kunming Medical University
基金 国家自然科学基金资助项目(81760064) 昆明医科大学研究生创新基金资助项目(2018S108)
关键词 心脏永久起搏器 电磁兼容 核磁共振成像 高频电刀 Heart permanent pacemaker Electromagnetic compatibility Magnetic resonance imaging High-frequency electric knife
  • 相关文献

参考文献3

二级参考文献27

  • 1Guang-Wei Ji,Yuan-Zhi Wu,Xu Wang,Hua-Xiong Pan,Ping Li,Wan-Ying Du,Zhi Qi,An Huang,Li-Wei Zhang,Li Zhang,Wen Chen,Guang-Hua Liu,Hui Xu,Quan Li,Ai-Hua Yuan,Xiao-Ping He,Guo-Hua Mei.Experimental and clinical study of influence of high-frequency electric surgical knives on healing of abdominal incision[J].World Journal of Gastroenterology,2006,12(25):4082-4085. 被引量:24
  • 2Silvetti MS, Drago F, Grutter G, et al. Twenty years of paediatric cardiac pacing: 515 pacemakers and 480 leads implanted in 292 patients [ J ].Europace, 2006,8 : 530-536.
  • 3Welisch E, Cherlet E, Crespo-Martinez E, et al. A single institution experience with pacemaker implantation in a pediatric population over 25 years [ J ]. Pacing Clin Electrophysiol, 2010, 33: 1112- 1118.
  • 4Kim JJ, Friedman RA, Eidem BW, et al. Ventricular function and long-term pacing in children with congenital complete atrioventric- ular block [ J ] .J Cardiovasc Electrophysiol, 2007,18 : 373-377.
  • 5Olgun H, Karagoz T, Celiker A, et al.Patient- and lead-related fac- tors affecting lead fracture in children with transvenous permanent pacemaker[ J].Europace,2008,10: 844- 847.
  • 6Celiker A, Baspinar O, Karagoz T. Transvenous cardiac pacing in children : problems and complications during follow-up [ J ].Anadolu Kardiyol Derg, 2007,7 : 292- 297.
  • 7Fortescue EB, Berul CI, Cecchin F, et al. Patient, procedural, and hardware factors associated with pacemaker lead failures in pediat- rics and congenital heart disease [ J ]. Heart Rhythm, 2004,1 : 150- 159.
  • 8Ellenbogen KA, Stambler BS, Orav E J, et al.Clinical characteristics of patients intolerant to VVIR pacing[ J ].Am J Cardiol, 2000,86 : 59-63.
  • 9Lamas GA, Orav E J, Stambler BS, et al. Quality of life and clini- cal outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. Pacemaker Selection in the Elderly Investigators[ J]. N Engl J Med, 1998,338 : 1097- 1104.
  • 10Horenstein MS. Karpawich PP. Pacemaker syndrome in the young: do children need dual chamber as the initial pacing mode? [ J]. Pacing Clin Electrophysiol, 2004,27 : 600- 605.

共引文献12

同被引文献10

引证文献1

相关作者