期刊文献+

某干船坞主排水泵导流体法兰断裂原因分析及修复 被引量:1

Analysis and repair of flange fracture of main drainage pump plange in a dry dock
下载PDF
导出
摘要 文章通过对某干船坞1号主排水泵的现场检查,根据导流体下支撑法兰断裂部分的实际情况,利用材料折断原理分析并得出导流体法兰的断裂原因,同时根据实际工程情况利用钢片拼接螺栓固定方法加以修复,对以后此类泵的运行维护及维修保养提供了经验和范例。 Based on the site inspection of the No. 1 main drainage pump in a dry dock, according to the actual condition of the fracture part of the supporting flange under the diversion body, the paper analyzes the fracture reason of the flange with the material fracture principle and obtains the reason of the fracture of the flange. At the same time, according to the actual engineering situation, the steel splicing bolt fixing method is used to repair this kind of pump, which provides experience and example for the operation and maintenance of this kind of pump in the future.
出处 《中国修船》 2019年第3期30-32,共3页 China Shiprepair
关键词 船坞排水泵 泵导流体 维修保养 dock drain pump pump guide repair and maintenance
  • 相关文献

参考文献1

二级参考文献4

  • 1SL317-2004泵站安装及验收规范
  • 2GB50265-2010[S].泵站设计规范.
  • 3GB50275压缩机、风机、泵安装工程施工及验收规范.
  • 4GB/T13008-91清水泵、混流泵技术条件.

同被引文献4

引证文献1

相关作者

内容加载中请稍等...