摘要
本文旨在针对除湿机水满保护机构的可靠性设计,应用6σ(Sixsigma)技术分析,从DMADV五个阶段(Define、Measure、Analyze、Design和Verify)进行分析,再设计、再验证来解决空箱报警的问题,并确保我司除湿机产品水满保护机构模块化设计的可靠性。
This paper aims at the dehumidifier water full protection mechanism reliability Design, application 6sigma technology analysis, from the DMADV five stages(Define, Measure, Analyze, Design and Verify) analysis, re-design, re-verify to solve the problem of empty tank alarm, and ensure our dehumidifier products water full protection mechanism modular design reliability.
作者
刘发申
LIU Fashen(Guangdong Midea refrigeration equipment Co., Ltd. Fushan 528311)
出处
《家电科技》
2019年第3期96-101,共6页